4
NOTE: To avoid electromagnetic interference when the reader is connected
to a CBX connection box, verify the jumper positions in the CBX as indicated
in its Installation Manual.
4.1 POWER SUPPLY
Power requirements and conditions depend on the Matrix 300N model: Standard or PoE
(Power over Ethernet).
4.1.1 Standard Models
For these models power can be supplied to the reader through the CBX100/500 spring clamp
terminal pins as shown in Figure 30:
The power must be between 10 and 30 Vdc only.
It is recommended to connect the device CHASSIS to earth ground (Earth) by setting the
appropriate jumper in the CBX connection box. See the CBX Installation Manual for details.
4.1.2 Power over Ethernet (PoE) Models
The Ethernet pinout is as follows:
Figure 31 - M12 D-Coded Female Ethernet Network Connector
Pin
1
2
3
4
62
Power Supply
VGND
V+
Earth
in
Ground
Figure 30 - Power Supply Connections
3
Power over Ethernet Network Connector Pinout
Name
Function
TX +/DC-
Transmitted data (+) DC power (-)
RX +/DC+
Received data (+) DC power (+)
TX -/DC-
Transmitted data (-) DC power (-)
RX -/DC+
Received data (-) DC power (+)
MATRIX 300N™ REFERENCE MANUAL
4
1
2