TROUBLESHOOTING
Problem
One Shot or Phase Mode
using serial trigger source:
the "TRIGGER" LED is not
blinking.
Phase Mode:
the
"TRIGGER"
correctly blinking but no image
is displayed in the DL.CODE
window.
Continuous Mode:
the "TRIGGER" LED is not
blinking.
Any Operating Mode:
the
"TRIGGER"
correctly blinking but no result
is transmitted by the reader at
the end of the reading phase
collection.
Image not clear:
Image
focused
decoded:
Reading:
the reader always transmits
the No Read Message
Communication:
reader
is
not
transmitting
anything to the host.
TROUBLESHOOTING GUIDE
Suggestion
On the Reading Phase step check the settings for
Acquisition
Reading Phase-OFF parameters.
Are the COM port parameters (Baud Rate, Parity, Data
Bits, Stop Bits) correctly assigned?
On the Reading Phase step check the settings of
Acquisition Trigger String, Reading Phase-ON
String, and Reading Phase-OFF String parameters.
Is the serial trigger source correctly connected?
Is the Phase frequency lower than the maximum frame
LED
is
rate?
Verify the correct software configuration settings.
Check the Code Collection parameters on the Reading
LED
is
Phase step and the Data Formatting parameters on the
Data Formatting step.
verify the Focus procedure
but
not
verify the Calibrate Image Density procedure.
Run the Rapid Configuration procedure in chapter 1.
Position the reader as described in par. 3.3 and through
DL.CODE:
Tune the Acquisition Delay on Trigger, if the moving
code is out of the reader field of view;
Set the Continuous Operating Mode if no external
trigger source is available;
Tune the Image Setup to improve the code image
quality;
Check the parameter settings in the Code Setup
step: 2D Codes, 1D Codes, and Postal Codes;
View the full resolution code image to check the
printing or marking quality.
Is the serial cable wiring correct?
If using CBX, be sure the RS422 termination switch is
OFF.
Are the host serial port settings the same as the reader
serial port settings?
In DL.CODE Device menu > Settings > Settings > LED
Configuration,
configured to indicate Main Serial Port TX or Main
Serial Port RX.
Trigger,
Reading
the
COM
LED
9
Phase-ON,
and
Function
can
be
151