PREPARATION FOR INSPECTION AND ADJUSTMENT OF MAIN PCB

● In case of replacing the main PCB, SWM unit or MR encoder unit, be sure to adjust the following items due to a
  necessity on the operation.
1.Items to adjust
 ・Adjustment of MR duty
 ・Adjustment of driving frequency and motor control
2.Equipment and tools to be required
 ・Single output rated voltage power supply: 1 unit
  For contact A to mount: Output of the DC/DC converter (5.5V 100mA)
  For contact F to contact G: 6.0V 3.0A
 ・Oscilloscope: 1 unit for adjusting the MR duty/adjusting the driving frequency and motor control
 ・AF-I communication box (J15306 or J15306-1): 1 unit
 ・AF-I communication adapter (J15307): 1 unit