Installation Instructions
SECTION SIX
Gas Type:
Gas Pressure:
Pressure Test Point Location:
Gas Input:
Injectors:
Oxy pilot:
NOx Classification .................... 5
Gas Connection:
Data Badge Location:
Battery
Remote handset size 3 x 1.5v AAA,
Appliance 6 x 1.5V C high power alkaline.
Appliance Dimension
NOTE: The efficiency of this appliance has been measured as specified in BS7977-1 2009 +A1:2013
and the result is 73.67 %. The gross calorific value of the fuel has been used for this efficiency
calculation. Gastec have certified the test data from which it has been calculated. The efficiency
value may be used in the UK Government's Standard Assessment Procedure (SAP) for energy rating
of dwellings. Please note: Within the appliance packaging will be a outlet restrictor, this is there to
achieve the maximum efficiency. This, however, may not be fitted due to the flue underperforming.
When unpacking the appliance please check the following items are included:
Fuel Bed:
Owners Manual
Appliance Data
NATURAL GAS
CATEGORY I 2 H
20 mbar +/- 1.0mbar
Gas inlet elbow
5.5 kW Gross (Max.)
2.4 kW Gross (Min.)
Mk 360
9102 N.G.
8mm compression: semi-rigid or rigid
Located on the base of the appliance on the R/H side beneath the
grill.
Air Tray
Fireplace Frame Assembly.
Vermiculite
14
PROPANE GAS
CATERGORY 1 3 P
37 mbar +/- 1.0mbar
5.0kW Gross (Max.)
2.4kW Gross (Max.)
Mk 116
9264 L.P.G.
LT 6117 (12/13 Iss 11)