Movincool office Pro 12 Operation Manual

Movincool office Pro 12 Operation Manual

Portable
Hide thumbs Also See for office Pro 12:

Advertisement

OPERATION
MANUAL
OFFICE PRO 12 and OFFICE PRO 24
READ THIS MANUAL CAREFULLY FOR INSTRUCTIONS ON CORRECT
INSTALLATION AND USAGE, AND READ ALL SAFEGUARDS.
~
'
SECCION EN ESPANOL
SECTION EN FRANÇAIS

Advertisement

Table of Contents
loading

Summary of Contents for Movincool office Pro 12

  • Page 1: Operation Manual

    OPERATION MANUAL OFFICE PRO 12 and OFFICE PRO 24 READ THIS MANUAL CAREFULLY FOR INSTRUCTIONS ON CORRECT INSTALLATION AND USAGE, AND READ ALL SAFEGUARDS. ‘ SECCION EN ESPANOL SECTION EN FRANÇAIS...
  • Page 2 All rights reserved. This book may not be reproduced or copied, in whole or in part, without the written permission of the publisher. DENSO SALES CALIFORNIA, INC. reserves the right to make changes without prior notice. MovinCool is a registerd trademark of DENSO Corporation.
  • Page 3 OPERATION MANUAL OFFICE PRO 12 and OFFICE PRO 24...
  • Page 5: Table Of Contents

    Table of Contents FOREWORD ..................1 Definition of Terms ..............1 GENERAL WARNINGS & CAUTIONS ..........2 INVENTORY ..................3 INSTALLATION ................. 4 Choosing an Installation Site ............ 4 Moving the Unit ................5 Plugging in the Unit ..............6 FEATURES ..................
  • Page 7: Foreword

    FOREWORD Congratulations on purchasing the MovinCool portable air conditioner. This manual explains how to install and operate the MovinCool Office Pro 12 and Office Pro 24 portable air conditioning units. Please read this operation manual thoroughly to familiarize yourself with the fea- tures of the unit and to ensure years of reliable operation.
  • Page 8: General Warnings & Cautions

    115 V, 15 A or equivalent. • The Office Pro 12 is equipped with a ten (10) foot (3 meter) power cord. The Office Pro 24 is equipped with a six (6) foot (1.8 meter) power cord. If replacement, fixed location (hard wired) or power...
  • Page 9: Inventory

    INVENTORY After unpacking your MovinCool unit, please check to make sure you have the following items: • Office Pro 12 or Office Pro 24 MovinCool Unit (1) • Operation Manual/Warranty Card (1) NOTE: If any of these items were not included in the box or appear damaged, please contact your MovinCool reseller for replacement.
  • Page 10: Installation

    • Install the unit in areas that can withstand the weight of the unit. The Office Pro 12 unit weighs approximately 200 lbs (91 kg) and the Office Pro 24 weighs approximately 245 lbs. (111 kg) (when the drain tank is full of water).
  • Page 11: Moving The Unit

    INSTALLATION (cont.) Moving the Unit Unlock the casters and push the MovinCool unit using the side handles to a flat, level surface and set the casters back to the LOCKED position. SIDE HANDLES UNLOCKED LOCKED...
  • Page 12: Plugging In The Unit

    This could result in electrical shock. CAUTION: • Office Pro 12 model ONLY: The AC outlet (115 VAC Single Phase, 60Hz) needs to be rated at 15A or higher. Do not share the outlet with any other instrument or equipment. •...
  • Page 13: Features

    FEATURES Both Models feature: • An electronic control panel, which allows the user to control the unit’s operation easily. • Dual fan speeds (either HIGH or LOW) in both COOL and Fan Only modes. • Digital display that indicates the temperature SET POINT (either Fahrenheit or Celsius) in which the COOL Mode will operate in.
  • Page 14: Operation

    OPERATION Control Panel Before operating the unit, it is important to familiarize yourself with the basic controls located on the control panel. ➀ COOL ON/OFF Activates/deactivates the COOL mode/ Button turns the unit off. ➁ FAN ON/OFF Activates/deactivates the HIGH or LOW Buttons fan mode.
  • Page 15 OPERATION (cont.) Control Panel (Cont.) ➆ Temperature Scale Illuminates to indicate the current temperatures being displayed are either in °C or °F; also displays the clock when programming. ➇ AM/PM LED Illuminates to indicate AM or PM time of day. ➈...
  • Page 16: Operating In Cool Mode

    OPERATION (cont.) Operating in COOL Mode ➀ The unit can be operated in COOL mode by pressing the COOL ON/OFF button (LED illuminates). NOTE: In COOL mode the unit can only be turned off by pressing the COOL ON/OFF button again, not by pressing the fan buttons. ➁...
  • Page 17: How To Set A Program

    OPERATION (cont.) How to Set a Program ➀ Setting a START TIME Press the Program SET button. The Program SET button and START TIME LEDs will illuminate. Press the HRS and MIN buttons to set the START TIME. ➁ Setting an END TIME Press the Program SET button until the END TIME LED illuminates.
  • Page 18 OPERATION (cont.) How to Set a Program (Cont.) NOTE: • The unit will return to the previous mode if a program is turned off while it is running. • The Program RUN LED flashes while a program is running. It is illuminated continuously when the program mode is activated.
  • Page 19: Operating Modes

    °C or °F. The unit has been preset from the factory to display the temperature(s) in °F. NOTE: If you wish to change the fan mode operation (COOL OPERATE to COOL STOP), and/or the Temperature Scale Display (°F to °C), contact your MovinCool reseller.
  • Page 20: Emptying The Drain Tank

    OPERATION (cont.) Emptying the Drain Tank During COOL mode, condensate will accumulate in the drain tank. When the drain tank becomes full, the FULL TANK LED will flash and the unit will shut off automatically. NOTE: If you want to empty the drain tank, while the unit is in operation, press the COOL ON/OFF button to turn the unit off.
  • Page 21: Drain Pump Kit (Optional)

    OPERATION (cont.) Drain Pump Kit (Optional) (Office Pro 12 model ONLY) A drain pump kit (CPK-3) is available to allow continuous operation and to eliminate the need for a drain tank. • When the water collects to level (A) in the pump reservoir, the drain pump begins to operate and discharges the water.
  • Page 22 OPERATION (cont.) DRAIN PUMP KIT (Optional) (Office Pro 24 model ONLY) A drain pump kit (CPK-5) is available to allow continuous operation and to eliminate the need for a drain tank. • When the water collects to level (A) in the pump reservoir, the drain pump begins to operate and discharges the water.
  • Page 23: Daily Inspection & Maintenance

    DAILY INSPECTION & MAINTENANCE Emptying the Drain Tank To empty the drain tank, refer to instructions on page 14. Cleaning the Air Filters Clean the air filters once a week. If the unit is used in a dusty environ- ment, more frequent cleaning may be required. A dirty air filter reduces air output resulting in a decrease of the cooling capacity.
  • Page 24: Filter Cleaning Method

    ➁ Check the power cord, plug and prongs for damage or excess play. If any damage or excess play is found, contact your MovinCool reseller for repair. ➂ Check the air filters and drain tank. ➃ Clean the outside of the unit(s) with a damp cloth or mild nonabrasive cleaner.
  • Page 25: Troubleshooting

    Clean air filters ➁ Air inlet/outlet blocked Clear air inlet/outlet ➂ Improper temperature setting Set to desired position If symptoms persist after the above actions have been taken, turn the unit off, disconnect the power cord plug and contact your MovinCool reseller.
  • Page 26: Technical Specifications

    TECHNICAL SPECIFICATIONS ITEM/FEATURES Office Pro 12 Office Pro 24 Rating Conditions dry bulb 95º F (35º C) 95º F (35º C) wet bulb 83º F (28.2º C) 83º F (28.2º C) humidity (60%) (60%) Specifications power frequency 60Hz 60Hz line voltage...
  • Page 27: Sección En Español

    LIMITED WARRANTY DENSO SALES CALIFORNIA, INC. ("DENSO") warrants its MOVINCOOL Products only to the extent stated in its official written warranties. Unless otherwise specifically provided in writing by DENSO, DENSO warrants to end- user that the Products shall be free of defects in materials or workmanship and will...
  • Page 28 DENSO SALES CALIFORNIA, INC. 3900 Via Oro Avenue Long Beach CA 90810-1868 800-264-9573 / 310-834-6352 www.movincool.com Technical Services Department DSCA P/N: LA990009-1218 Fourth Issue: April 2003 GAC P/N: LA484007-1421 Printed in the U.S.A.

This manual is also suitable for:

Office pro 24

Table of Contents