OPERATION MANUAL OFFICE PRO 12 / OFFICE PRO 18 / OFFICE PRO 24 Unit Serial Number Range: 0711XXXX### to Present (From July 2011 to Present) READ THIS MANUAL CAREFULLY FOR INSTRUCTIONS ON CORRECT INSTALLATION AND USAGE, AND READ ALL SAFEGUARDS SECCIÓN EN ESPAÑOL...
All rights reserved. This book may not be reproduced or copied, in whole or in part, without the written permission of the publisher. DENSO PRODUCTS AND SERVICES AMERICAS, INC. reserves the right to make changes without prior notice. MovinCool®, Office Pro®, and SpotCool® are registered trademarks of DENSO Corporation.
Page 3
OPERATION MANUAL OFFICE PRO 12 / OFFICE PRO 18 / OFFICE PRO 24...
Table of Contents SERIAL NUMBER LOCATION AND IDENTIFICATION........2 FOREWORD....................... 5 Definition of Terms....................5 GENERAL WARNINGS & CAUTIONS .............. 6 INVENTORY ....................... 7 INSTALLATION....................8 Choosing an Installation Site ................8 Moving the Unit ....................9 Plugging in the Unit ..................10 Warning Signal Connection ................12 Fire Alarm Control Panel Connection ............13 LCDI Power Cord Instruction .................14 FEATURES.......................
FOREWORD Congratulations on purchasing the MovinCool portable air conditioner. This manual explains how to install and operate the MovinCool Office Pro 12, Office Pro 18, and Office Pro 24 portable air conditioning units. Please read this operation manual thoroughly to familiarize yourself with the features of the unit and to ensure years of reliable operation.
MovinCool parts, purchased from an authorized reseller. 2. The proper electrical outlet for MovinCool units must be equipped with a UL recognized circuit breaker. 3. Because of potential safety hazards under a certain condition, we strongly recommend against the use of an extension cord.
After unpacking your MovinCool unit, please check to make sure you have the following items: 1. Office Pro 12 or Office Pro 18 or Office Pro 24 MovinCool Unit (1) 2. Operation Manual/Product Registration (1) Note: If any of these items were not included in the box or appear damaged, please contact your MovinCool reseller for replacement.
INSTALLATION Choosing an Installation Site CAUTION: Following are some precautions to consider before choosing your installation site. Please review carefully as improper installation may result in personal injury or damage to the unit. 1. Do not use the unit in areas where leakage of flammable gas may occur. 2.
INSTALLATION (cont.) Moving the Unit Unlock the casters and push the MovinCool unit using the side handles to a flat, level surface and set the casters back to the LOCKED position. Right Side Handle Left Side Handle UNLOCKED LOCKED...
2. Check the power cord, plug and prongs for damage or excess play. If any damage or excess play is found, contact your MovinCool reseller or a qualified technician for repair.
Page 11
INSTALLATION (cont.) Plugging in the Unit (cont.) CAUTION: The power source should be a dedicated single outlet circuit with UL recognized short-circuit and ground fault protective breaker. Do not share the AC outlet with any other instrument or equipment. The minimum power supply rating and the maximum fuse size for each corresponding model are listed below.
INSTALLATION (cont.) Warning Signal Connection (Output Signal Terminal L+ and L-) The controller is equipped with a warning signal output relay type (Form C, normal open dry contact) which can be used to monitor the failure condition. Relay contactor is closed when the following condition has occurred: a.
INSTALLATION (cont.) Fire Alarm Control Panel Connection (Input Signal Terminal E+ and E-) The controller is equipped with a normal open input signal connection, which can be connected directly from the fire alarm control panel. This input signal terminal should only be connected to a close or open dry contact signal. When receiving the signal from the fire alarm control panel, the unit turns off and does not turn back on until it has been RESET.
INSTALLATION (cont.) LCDI Power Cord Instruction WARNING The LCDI device is a non-serviceable device. Attempting to open the device may expose the user to the hazards of electric shock, and could void warranties of this product. Manufacturer’s reliability is limited to the replacement of the device. CAUTION 1.
FEATURES For all models: 1. A digital electronic control panel, which allows the user to easily control the unit’s operation. 2. Dual fan speeds (either HIGH or LOW) in both COOL and FAN ONLY modes. 3. Digital LCD display with blue backlight that indicates: a.
OPERATION Control Panel Before operating the unit, it is important to familiarize yourself with the basic controls located on the control panel. 1. COOL Mode Button Activates/deactivates the COOL mode/turns the unit off. 2. FAN Mode Button Activates/deactivates the high, low, and off fan speed.
OPERATION (cont.) Control Panel (cont.) LCD Indicators 9. MO...SU Illuminates to indicate selected day of the week. 10. °C or °F Temperature displayed in either Fahrenheit or Celsius (see Note). 11. AM/PM Illuminates to indicate AM or PM time of day. 12.
The unit has been preset at the factory for continuous fan operation. Note: If you want to change the fan mode operation (from OPERATE to STOP), contact your MovinCool reseller. 4. Temperature Scale Display DIP Switch The temperature scale display DIP switch changes the temperature(s) that are displayed to either °C or °F.
OPERATION (cont.) Set Clock Prior to operating the Office Pro 12, Office Pro 18, or Office Pro 24 users should set the clock of the controller to the correct time as shown in the following steps: 1. Press and hold the SET CLOCK button for 3 seconds or until beep.
OPERATION (cont.) Operating in FAN ONLY Mode 1. The unit can also be operated in FAN ONLY mode by pressing FAN HI/LO button (LCD indicates “FAN HI/LO” and “COOL OFF”). 2. The unit can then be turned off by pressing the FAN HI/LO button until fan turns off (FAN ONLY mode speed sequences are HI→LO→OFF).
OPERATION (cont.) How to Set a Program SET START TIME 1. Press and hold the SET PROG button for 3 seconds or until beep. 2. Press SET TEMP buttons to scroll day of the week. 3. Press ENTER button. Step 1 & 18 4.
OPERATION (cont.) How to View and Delete Program 1. Press and hold the SET PROG button for 3 seconds or until beep. 2. To view edited program - While pressing and holding the SET PROG button, press SET TEMP buttons ( ) to scroll program sequence.
The unit returns to the normal operation after the problem is fixed and the controller is RESET. To RESET: Press FAN HI/LO and COOL ON/OFF buttons simultaneously for 5 seconds. Contact your MovinCool reseller or a qualified technician if problem persists.
OPERATION (cont.) Empty the Drain Tank During COOL mode, condensate water accumulates in the drain tank. When the drain tank becomes full, the “TANK FULL” LED flashes and the LCD displays “TANK FL” and the unit turns off automatically. Note: If you want to empty the drain tank, while the unit is in operation, press the COOL ON/OFF button to turn the unit off.
OPERATION (cont.) Condensate Pump Kit (Optional) A condensate pump kits are available to allow continuous operation and to eliminate the need for a drain tank. When the water collects to level (A) in the pump reservoir, the condensate pump begins to operate and discharge the water.
DAILY INSPECTION & MAINTENANCE Empty the Drain Tank To empty the drain tank, refer to instructions on page 24. Clean the Air Filters Clean the air filters once a week. If the unit is used in a dusty environment, more frequent cleaning may be required.
2. Check the power cord, plug and prongs for damage or excess play. If any damage or excess play is found, contact your MovinCool reseller or a qualified technician for repair.
TROUBLESHOOTING Check the following items before calling your MovinCool reseller or a qualified technician. CONDITION POSSIBLE CAUSE REMEDY 1. Ground fault breaker trip or Reset breaker or reset power Unit does not operate. LCDI power cord trip. cord. 2. Drain tank is full.
Page 30
TECHNICAL SPECIFICATIONS (cont.) ITEMS/FEATURES Office Pro 12 Office Pro 18 Office Pro 24 Operating Conditions Inlet air: Maximum 95°F(35°C), 60%RH 95°F(35°C), 60%RH 95°F(35°C), 60%RH Minimum 65°F(18.3°C), 65°F(18.3°C), 65°F(18.3°C), 50%RH 50%RH 50%RH Control Device Temperature control Include Include Include Programmable timer Include Include Include...
PROCESSING, INJURY, GOODWILL, OR ANY OTHER CONSEQUENTIAL DAMAGES OF ANY KIND ARISING FROM BREACH OF THIS WARRANTY. DENSO PRODUCTS AND SERVICES AMERICAS, INC. reserves the right to make changes without prior notice. MovinCool®, Office Pro® and SpotCool® are registered trademarks of DENSO Corporation. PURCHASE DATE:...
Page 32
P/N: 484007-3582EN Third Issue: April 2013...