e) Check the junction box and diodes are well. If you have any diodes problem,
please contact the manufacturer.
f ) When clean the modules, it is not allowed to stand on the module or the likes. Like
below pictures show, this it prohibited.

5. Electrical specification

The module electrical rating are measured under Standard Test Conditions, which
2
are 1000W/m
, irradiance with AM 1.5 spectrum and 25 deg (77° F) ambient
temperature. The module might produce more or less voltage or current than rating
value in uncertainty condition. Accordingly, the values of I
module should be multiplied by a factor of 1.25 when determining component voltage
ratings, conductor current ratings, fuse sizes, and size of controls connected to the
PV output. Tables below are electrical characteristics of PV products at STC and the
tolerance of Isc,Voc,Vmp and Imp is ± 3%, except JKMxxxPP-72, JKMxxxPP-60
JKMxxxPP-72B series, JKMxxxPP-72, JKMxxxPP-60, JKMxxxPP-72B series is
± 10%.
5.1.
Electrical
JKMxxxP-72-J4, JKMxxxP-72B and JKMxxxPP-72B (xxx=250-320)
Series polycrystalline solar modules
specifications
of
- 14 -
and V
SC
OC
JKMxxxP-72,
JKMxxxPP-72,
marked on the