4
Loading Material
14
4.1.3
Setting the Material Sensor
Fig. 11
The material sensor (2) can be shifted perpendicular to the direction of media flow for adaptation to the media. The
sensor unit is marked with indentation (4) on the label sensor retainer.
Slightly loosen the screw (3) with Allen key (1).
Position sensor by moving it in such a way that the sensor can detect a reflex or cut-out mark.
Tighten the screw (3).
1
Setting the material sensor
2
3
4
14