Remote Ice Machine Usage With Non-Manitowoc Multi-Circuit Condensers - Manitowoc Indigo NXT Series Installation, Operation And Maintenance Manual

Hide thumbs Also See for Indigo NXT Series:
Table of Contents

Advertisement

Section 2
Remote Ice Machine Usage with Non-
Manitowoc Multi-Circuit Condensers
Warranty
The sixty (60) month compressor warranty,
including thirty six (36) month labor
replacement warranty, shall not apply when
the remote ice machine is not installed
within the remote specifications. The
foregoing warranty shall not apply to any
ice machine installed and/or maintained
inconsistent with the technical instructions
provided by Manitowoc Ice. Performance
may vary from Sales specifications. ARI
certified standard ratings only apply when
used with a Manitowoc remote condenser.
If the design of the condenser meets the
specifications, Manitowoc's only approval
is for full warranty coverage to be extended
to the Manitowoc manufactured part of
the system. Since Manitowoc does not
test the condenser in conjunction with the
ice machine, Manitowoc will not endorse,
recommend, or approve the condenser, and
will not be responsible for its performance
or reliability.

Important
Manitowoc
warrants
new and unused remote packages.
Guaranteeing the integrity of a new ice
machine under the terms of our warranty
prohibits the use of pre-existing (used)
tubing or condensers.
Part Number 000014141 Rev 07 2/20
only
complete
Design & Burst Pressure
Design Pressure 600 psig - 4137 kPa
Burst Pressure 2500 psig - 17237 kPa
Head Pressure Control Valve
Do not use a fan cycling control to try to
maintain discharge pressure. Compressor
failure will result. Any remote condenser
connected to a Manitowoc Ice Machine
must have the OEM head pressure control
valve installed. Manitowoc will not accept
substitute "off the shelf" head pressure
control valves.
Fan Motor
The condenser fan must be on during the
complete ice machine freeze cycle (do
not cycle on fan cycle control). The ice
maker has a condenser fan motor circuit
for use with a Manitowoc condenser. It is
recommended that this circuit be used to
control the condenser fan(s) on the multi-
circuit condenser to assure it is on at the
proper time. Do not exceed the rated amps
for the fan motor circuit listed on the ice
machine's serial tag.
Internal Condenser Volume
The multi-circuit condenser internal
volume must not be less than or exceed
that used by Manitowoc. Do not exceed
internal volume and try to add charge to
compensate, as compressor failure will
result.
Model
IT0500N
IF0500N
IF0600N/IF0900N
IT1200N
IT1500N/IT1900N
Installation
Minimum
Maximum
ft
(cm
)
ft
(cm
3
3
3
0.020
0.030
(566)
(850)
0.045
0.060
(1274)
(1699)
0.085
0.105
(2407)
(2973)
)
3
33

Hide quick links: