Installation Instructions - Manitowoc Q 800 Installation And Use Manual

Manitowoc marine q 800 ice machine installation and owner/operator use and care manual
Hide thumbs Also See for Q 800:
Table of Contents

Advertisement

Section 2
WATER SUPPLY AND DRAIN LINE SIZING ILLUSTRATION
18.00" VENT
(45.70 cm)
(SEE BELOW)
BIN DRAIN FITTING
3/4" F.P.T (1.91 cm)
CONDENSER WATER
DRAIN FITTING
1/2" F.P.T. (1.27 cm)
ICE MAKING WATER
INLET FITTING
3/8" F.P.T. (0.95 cm)
ICE MAKING WATER
INLET TUBING
3/8" MIN. I.D. (0.95 cm)
ICE MAKING WATER
DRAIN FITTING
1/2" F.P.T. (1.27 cm)
SLOPE
ICE MAKING WATER
DRAIN TUBING
1/2" MIN. I.D. (1.27 cm)
VENT
BIN DRAIN TUBING
3/4" MIN. I.D. (1.91 cm)
Typical Water Supply Drain Installation

Installation Instructions

CONDENSER WATER
INLET FITTING
1/2" F.P.T. (1.27 cm)
CONDENSER WATER
INLET TUBING
1/2" MIN. I.D. (1.27 cm)
CONDENSER WATER
DRAIN TUBING
1/2" MIN. I.D. (1.27 cm)
18.00"
(45.70 cm)
OPEN, TRAPPED OR
VENTED DRAIN
WATER SHUT
OFF VALVE
VENT
SV1626
2-5