Maintenance
Water Distribution Tube
1. Disconnect the water hose from the distribution
tube.
1. LIFT UP
2. SLIDE BACK
3. SLIDE TO RIGHT
DISTRIBUTION
TUBE
THUMBSCREW
Water Distribution Tube Removal
1. Loosen the two thumbscrews, which secure the
distribution tube.
2. Lift the right side of the distribution tube up off
the locating pin, then slide it back and to the
right.
Do not force this removal. Be sure the locating pin
is clear of the hole before sliding the distribution
tube out.
3. Disassemble for cleaning.
A. Twist both of the inner tube ends until the
tabs line up with the keyways.
B. Pull the inner tube ends outward.
INNER
TUBE
Water Distribution Tube Disassembly
4-8
2
3
1
LOCATING PIN
SV1620
CAUTION
INNER
TUBE
TAB
KEYWAY
SV1211
Water Curtain
1. Gently flex the curtain in the center and remove it
from the right side.
THUMBSCREW
2. Slide the left pin out.
Water Curtain Removal