Installation Instructions

Water Service/Drains

Water Inlet Lines
Follow these guidelines to install water inlet lines:
• Do not connect the ice machine to a hot water
supply. Be sure all hot water restrictors installed
for other equipment are working. (Check valves
on sink faucets, dishwashers, etc.)
• If water pressure exceeds the maximum
recommended pressure, obtain a water pressure
regulator from your Manitowoc distributor.
• Install a water shut-off valve for both the ice
making and condenser water lines.
• Insulate water inlet lines to prevent condensation.
• Use teflon tape to seal threaded fittings.
Important
Install sump trough drain plug before starting the
ice machine.
WATER SUPPLY AND DRAIN LINE SIZING/CONNECTIONS
Location
Ice Making
Water Inlet
Ice Making
Water Drain
Condenser
Water Inlet
Condenser
Water Drain
Bin Drain
2-4
Water
Temperature
33°F (0.6°C) Min.
20 psi (137.9 kPA) Min.
90°F (32.2°C)
80 psi (551.5 kPA) Max.
Max.
---
33°F (0.6°C) Min.
20 psi (137.9 kPA) Min.
90°F (32.2°C)
150 psi (1034.2 kPA)
Max.
---
---
Drain Connections
Follow these guidelines when installing drain lines to
prevent drain water from flowing back into the ice
machine and storage bin:
• Drain lines must have a 1.5 inch drop per 5 feet
of run (2.5 cm per meter), and must not create
traps.
• The floor drain must be large enough to
accommodate drainage from all drains.
• Run separate bin and ice machine drain lines.
Insulate them to prevent condensation.
• Vent the bin and ice machine drain to the
atmosphere. Do not vent the condenser drain on
water-cooled models.
Plumbing must conform to applicable
codes.
Water
Ice Machine
Pressure
3/8" Female
Pipe Thread
1/2" Female
---
Pipe Thread
Max.
1/2" Female
---
Pipe Thread
3/4" Female
---
Pipe Thread
CAUTION
Tubing Size Up to Ice
Fitting
Machine Fitting
3/8" (9.5 mm)
minimum inside
diameter
1/2" (12.7 mm)
minimum inside
diameter
3/8" Female Pipe Thread
1/2" (12.7 mm)
minimum inside
diameter
3/4" (19.1 mm)
minimum inside
diameter
Section 2