Figure 3.4 Valve Assembly Removal
D. Burner Identifi cation/Verifi cation
The burner may be accessed for identifi cation and verifi cation purposes. This task should be performed by a qualifi ed ser-
vice technician. The base refractory, valve plate and grate do not need to be removed to access the burner assembly. The
logs and fi ber burner top need to be removed to access the burner. Disconnect the pilot from the burner before removal.
See Figure 3.5 for burner identifi cation chart. Notch patterns are located on bottom side of burner.
6000CL
6000CLX
8000CL
8000CLX
Figure 3.5 Burner Identifi cation
NOTCH LOCATION
NG
LP
Heat & Glo • 6000C-IPI, 8000C-IPI • 2164-900 Rev. AB • 10/15