2. Front Body
Disconnect Connectors
・ Disconnect the FPC ① , ② , ③ , and ④ from each connector in order.
Eyepiece unit
Metering FPC unit
・ Take out 2 screws (#631) so that the eyepiece unit
(#B261) with the Metering FPC unit(#B2008)
attached can be removed.
#631×2
#B2008
#B261
- D14 ・
① #B2163
#B2008
Note: The eyepiece unit (#B261) and
unit
(#B2008) is attached with the adhesive. Unless
replacement is necessary, do NOT disassemble them.
In case of disassembling them or turning the screws
(#291), AE CCD position adjustment (ref. Assembly
Chapter) is necessary.
-
VBA10401-R.3623.A
① #B1008
② #1026
④ #B1025
#291×2
#290
#B261
Metering FPC