Installing the cassette heaters (option)

Installing the cassette heater requires the following component:
Two (2) cassette heaters (P/N 302FB25051): for 220 - 240 V specifications only
Two (2) cassette heaters (P/N 302FB25060): for 120 V specifications only
Two (2) cassette heater retainers (P/N 5A707690)
Six (6) M4 x 6 IT tap-tight (S-tight) screws (P/N 37611570)
Relay wire (P/N 5A707890)
Ten (10) wire saddles (P/N M2109000)
Procedure
1. Remove two screws from each of the right
cover and left cover 3 and then the covers.
2. Remove three screws holding the paper
feeder rear cover and then the cover.
3. Open the paper feeder.
4. Remove two screws holding the paper con-
veying unit assembly and then the assem-
bly.
5. Fit the cassette heaters to the cassette
heater retainers using two screws and wire
saddle for each.
6. Fit the cassette heater retainers to the left
and right of the paper feeder using one
screw for each.
7. Pull the cassette heater cable out to the
machine rear through the cable hole.
Cassette heater
Wire saddle
Cassette heater retainer
Machine left
Paper conveying unit assembly
Figure 1-2-2
Screws
Screws
Figure 1-2-3
5H0-4
Screw
Screw
Cassette heater
Wire saddle
Cassette heater retainer
Machine right
1-2-3