Test Tones; Gpi Setup; System Options Menu (Left) And Preferences Menu (Right) - Linear Acoustic AERO.qc User Manual

Audio quality controller with optional hd/sd-sdi and dolby decoding
Table of Contents

Advertisement

Linear Acoustic AERO.qc User Guide
Figure 4-4 System Options menu (left) and Preferences menu (right).
4.1.4

Test Tones

Test Tones – Multiple setup tones are available to calibrate the AERO.qc and other
downstream equipment. The Level control is self-explanatory, and is set at the standard –
20 dBFS reference level and adjusts the overall level of the test signals. On/Off turns the
selected test signal on or off while Cycle determines which channels will reproduce the
selected test signal. It can be adjusted to cycle through all channels, all channels of just the
main program (default), and individual channels.The available test signals are:
Sine – 1 kHz sine wave
Voice – Voice ID of all selected channels
Pink Noise – Equal energy-per-octave noise
White Noise – Equal level-per-octave noise
Brown Noise – Low-pass-filtered noise
Brown Nose – Try it (because broadcast audio is a funny business)
BLITS – Black and Lane Identification Test Signal (multichannel identification tones)
4.1.5

GPI Setup

The AERO.qc supports four GPI inputs which can be controlled by contact closures via
the rear-panel GPI/O connector. Once the GPI functions are set and GPI is enabled, ad-
ditional changes are not allowed until GPI is disabled.
GPI Input A-D - Disable, Monitor Preset 1-6, Run/Stop, Apply, Reset, Next Screen.
27
Detailed Operation

Advertisement

Table of Contents
loading