Problem
No
Yes
The lid doesn't latch
No
No
The bottom plate temperature is not
reaching the temperature setting
The lid never latch
No
the lid doesn't latch after some
cycles but restart to latch after
a while
Check if ...
the top heating element is absor-
bing current with the Multimeter
(approx. 4amps)
cabling between terminal block
and the board (connector 5) is
connected
the board is not giving power to the
heating elements through the relay
(voltmeter in connector 5 of the
board, 208 V - 230V for CE version)
cabling of the bottom plate to the
board, connector 4 is connected on
position 4 on the power board.
the probe connector INF is connected
in position INF on the board ( lum-
berg black connector.
the bottom heating element is ab-
sorbing current with the Multimeter
(approx. 4amps)
the board is not giving power to
the heating elements through the
relay (voltmeter in connector 4 of
the board)
Yes: Check ...
the handle reaches the right posi-
tion to the electromagnet
the electromagnet and/or the
washer are dirty
if the handle magnets are in place
the handle pins are blocked
screw of the washer is tight
cables of the electromagnet and
magnetic detectors are connected
(Connector 10)
electromagnet is working by a continuity
test from the connector 10
from connector 10 there is nominal
voltage when closing the lid
magnetic detectors are working by
a continuity test from the connectors
14/15 (by closing the lid)
the bimetallic sensors (CLK1 and
CLK2) are working by a continuity
test from the pins of the connector
3 (from the two left and the two right
contacts)
KS1 is working by visually checking
if the indicator move from the initial
position and the power coming in
there is enough free clearance for
the airfl ow from the exhaust pipes in
the rear of the machine
15/38
If not, action to do
replace the upper plate kit
connect the wires
replace the board
connect the wires
Connect the connector INF on the
board
replace the heating element of the
bottom plate
replace the board
remove all obstacles and/or check
for mechanical frictions
make a proper cleaning
replace the handle
try to unblock or replace the handle
readjust the latching system
connect the wires
change the electromagnet
replace the board if the power
supply is suitable
readjust or change the magnetic
detectors
change the bimetallic sensor failed
reconnect the wires or replace the
contactor
give the clearance according to the
installation diagram