Problem
No
The lid doesn't open automati-
cally at the end of the cycle
No
Panino doesn't reach the
desired core temperature
No
HSPP tech GB 03 09
No
Yes
the handle is moving
No
the handle is blocked
Yes
No Error codes
No
Indicates Error Codes Err4 or
Err5
Indicates Error Codes Err6
Check if ...
there is an airfl ow from the exhaust
pipes in the rear of the machine
the fan cabling is connected
there is power supply on both
magnetron fans (connector 7 on the
board - from the two left and the two
right contacts)
the magnetron fans are working with
an ohmmeter
Yes: Check ...
there is free movement by verifying:
- the opening of the lid
- no friction between lid and working
top
the handle pins are pushing out
lid springs are lifting the lid
there is free movement between
handle and the lid
electromagnet is releasing the
handle at the end of the cycle
Yes: Check ...
the right program was chosen
the programs have the right para-
meters
high voltage wiring from the
secondary of transformer are well
connected and not damaged
the magnetron fuses are working
capacitors are undamaged
diode and resistor are undamaged
Result: Magnetron is broken
The voltage to inlet is at least 1956V
for 208V machine and 367V for a
400V machine.
the three phases are correctly
connected in the main plug. ( for
EU machines )
If the fuse FS of the board is OK.
screw of the washer is tight
if the handle magnets are in place
16/38
If not, action to do
reconnect the exhaust pipes to the
exhaust pipes support or remove
possible clogging obstacles inside
the pipes
reconnect the wires of the fan
replace the board
replace the broken fan
assure free movement
try to unblock or replace the handle
adjust the spring tension or replace
them if broken
assure free movement
replace the board
use the right one
set the right parameters
reconnect them or replace if
damaged
replace them
replace it
replace them
replace following the error code
problem not related to the unit
Connect the wires to have three
phases + neutral.
replace the fuse FS with the spare part
fuse on the board and before restart
the machine check the adjsutment of
Microswicth S3. => Follow the pro-
cess indicated in the repair section
readjust the latching system
replace the handle