Venting

Caution: Only Flex Liner kit (MIND.FL25) or an approved
gas vent fl ue liner and a Vent Terminal (MIND.VTTERM)
is approved for use with this appliance.
Also approved for use is Simpson Dura-Vent GS
termination kits, both Standard Vertical Termination
cap (#980) and the Extended Vertical Termination cap
(#930) in conjunction with the 3" Co-Linear Termination
kit (#923GK).
No other venting system or components may be
used.
1) Measure chimney height and cut fl ex liner as required.
Mark one of the pipes to identify combustion air intake
pipe from fl ue outlet pipe.
2) Attach marked fl ex liner pipe to the intake side (longer
collar) of vent terminal. Seal and secure with sealant
and screws provided. Attach the other pipe to the
outlet side of vent terminal. Seal and secure with
sealant and screws provided.
3) Insert both fl ex liners from top of the chimney, down
through the damper opening.
4) The vent terminal is sized to fi t most typical chimneys.
Before attaching vent terminal to top of chimney,
apply a bead of caulking to top of clay liner. Slip vent
terminal over liner and secure in place with lateral
retaining bolts.
5) For larger chimneys, an optional fl ashing is available
which may be cut and fi tted to suit. The fl ashing
attaches to the underside of the terminal with four
nuts provided. Caulk the fl ashing in place to seal
any gaps.
Fig # 6
6
161204-24
Fig # 7
Gas Insert
Note: The vent must be a minimum 10' long
and must not exceed a total length of 35'.
Fig # 8
Vent Terminal
Seal
Min. ........10' (3 m)
Max. ........35' (10.7m)
3" Flex
Liner
# 5055.6591