Direct Wire Connection
Direct wire strain relief
g-Wire
Direct
Wire
Connection
IMPORTANT: A 4-wire connection
is required for mobile homes
and where local codes do not permit 3-wire connections.
, Prepare
your 4-wire
cable
for direct
connection
Unscrew the removable conduit connector (A) and any
screws from a 3/4" (19 mm) UL listed strain relief (UL marking
on strain relief). Put the threaded section of the strain relief
(C) through the hole below the terminal block opening (B).
Reaching inside the terminal block opening, screw the
removable conduit connector (A) onto the strain relief threads
and tighten securely.
/
Direct wire cable must have 5 ft. (1.52 m) of extra length so
dryer may be moved if needed.
Strip 5" (127 mm) of outer covering from end of cable,
leaving bare ground wire at 5" (127 mm). Cut 11/2'' (38 mm)
from remaining 3 wires. Strip insulation back 1" (25 mm).
Shape ends of wires into hooks.
Prepare
to connect
neutral
ground
wire and neutral
wire
Put direct wire cable through the strain relief. The strain
relief should have a tight fit with the dryer cabinet and be in
a horizontal position. Tighten strain relief screw against the
direct wire cable.
if your wiring looks like this:
4-wire direct connection:
Go to "4-Wire Direct Wire Connection"
on this page.
3-wire direct connection:
Go to "3-Wire Direct Wire Connection"
on page 11.
Remove center terminal block screw (B). Remove neutral
ground wire (E) from green external ground conductor screw (A).
f3,
onnect
neutral ground wire and
neutral wire
10
Connect neutral ground wire (E) and place
hooked end (hook facing right) of neutral wire
(white or center wire) (C) of direct wire cable
under center screw of terminal block (B).
Squeeze hooked ends together and tighten screw.