Fire Hazard
Cover unused exhaust holes with a manufacturer's
exhaust cover kit.
Contact your local dealer.
Failure to follow these instructions can result in death,
fire, electrical
shock, or serious injury.
Optional
exhaust
installations:
This dryer can be converted to exhaust out the right side, left
side (all models except WED71 HEB), or through the bottom.
If you prefer, you may contact your local dealer to have the dryer
converted.
Z
S
S
A
B
C
A. Standard rear offset exhaust installation
B. Left- or right-side exhaust installation
C. Bottom exhaust installation
Special
provisions
for mobile
homes:
Exhaust vent must be securely fastened to a noncombustible
portion of mobile home and must not terminate beneath the
mobile home. Terminate exhaust vent outside.
O
Determine
vent path:
m Select route that will provide straightest and most direct
path outdoors.
m Plan installation to use fewest number of elbows and turns.
m When using elbows or making turns, allow as much room
as possible.
m Bend vent gradually to avoid kinking.
m Use as few 90 ° turns as possible.
Determine
vent length and elbows
needed
for best
drying
performance:
m Use the following "Vent System Charts" to determine type of
vent material and hood combinations
acceptable to use.
NOTE: Do not use vent runs longer than those specified
in "Vent System Charts."
Exhaust systems longer than those specified will:
m Shorten life of dryer.
m Reduce performance,
resulting in longer drying times
and increased energy usage.
The "Vent System Charts" provide venting requirements that
will help achieve best drying performance.
Standard
Vent System
Chart
Number
of
Type
Angled
90 ° elbows
of vent
hoods
0
Rigid metal
64 ft. (20 m)
1
Rigid metal
54 ft. (16.5 m)
2
Rigid metal
44 ft. (13.4 m)
3
Rigid metal
35 ft. (10.7 m)
4
Rigid metal
27 ft. (8.2 m)
f
Long Vent System
Chart*
"
Number
of
Type
Angled
90 ° elbows
of vent
hoods
0
1
2
3
4
Rigid metal
Rigid metal
Rigid metal
Rigid metal
Rigid metal
160 ft. (48.8 m)
150 ft. (45.7 m)
140 ft. (42.7 m)
130 ft. (39.6 m)
120 ft. (36.6 m)
*For Model WED71 HEB only; for all other models, refer to the
Standard Vent System Chart above. To find your model number,
refer to the model and serial number plate in the inner door well.
NOTE: For long vent systems, use of box/Iouvered
hoods will
improve venting regardless of length.
14