Performance Data Sheet - Kenmore 10658143802 Use & Care Gude

Table of Contents

Advertisement

Available languages

Available languages

PERFORMANCE DATA SHEET
Base Grille Water Filtration
System
Model TIKB1/TIRFKB1
Capacity
100 Gallons
(379 Liters)
System
tested and certified
by NSF Internat!onal
against
NSF/ANSI
Standard
42 for the reduction
of
Chlorine
Taste and Odor, Particulate
Class I ; and against
NSF/ANSI
Standard
53 for the reduction
of
Lead, Mercury,
Atrazine,
Benzene,
Toxaphene,
O-Dichlorobenzene,
Cysts, Turbidity, Asbestos,
Lindane,
Tetrach oroethy ene, Endr n, A ach or, Ch orobenzene,
Ethy benzene,
TTHM, MTBE and VOC.
This system
has been tested
according
to NSF/ANSI
Standards
42 and 53 for the reduction
of the substances
listed below. The
concentration
of the indicated
substances
in water entering
the system was reduced
to a concentration
less than or equal to the
permissible
limit for water leaving the system,
as specified
in NSF/ANSI
Standards
42 and 53.
Substance
Reduction
NSF Reduction
Average
Influent Challenge
Maximum
Average
Minimum %
Aesthetic Effects
Requirements
Influent
Concentration
Effluent
Effluent
Reduction
Chlorine Taste/Odor
50% reduction
2.0 mg/L
2.0 mg/L + 10%
0.08 mg/L
2.0 mg/L
95.93
Particulate Class I*
85% reduction
3533333#/mL
At east 1O,OOOpart c es/mL
22000 #/mL**
11567 #/mL
99.38
Contaminant
NSF Reduction
Average
Influent Challenge
Maximum
Average
Minimum %
Reduction
Requirements
Influent
Concentration
Effluent
Effluent
Reduction
Lead: @ pH 6.5
0.010 mg/L
150 ug/L
0.15 mg/L + 10%
1.0 ug/L
1 ug/L
99.33
Lead: @ pH 8.5
0.010 mg/L
157 ug/L
0.15 mg/L _+10%
2.0 ug/L
1.08 ug/L
98.72
Mercury: @ pH 6.5
0.002 mg/L
0.0058 mg/L
0.006 mg/L + 10%
0.0002 mg/L
0.0002 mg/L
96.53
Mercury: @ pH 8.5
0.002 mg/L
0.0057 mg/L
0.006 mg/L _+10%
0.0002 mg/L
0.0002 mg/L
96.5
Benzene
0.005 mg/L
15 ug/L
0.015 mg/L _+10%
0.5 ug/L
0.5 ug/L
96.67
O-Dichlorobenzene
0.6 mg/L
1750 ug/L
1.8 _+ 10%
1 .Oug/L
1.O ug/L
99.94
Toxaphene
Atrazine
Asbestos
Live Cysts _
Turbidity
Alachlor
Endrin
Ethylbenzene
Lindane
Chlorobenzene
Tetrachloroethylene
TTHM
MTBE
VOC
0.003 mg/L
0.003 mg/L
99%
>99.95%
0.5 NTU
0.002 mg/L
0.002 mg/L
0.7 mg/L
0.002 mg/L
0.6 mg/L
0.005 mg/L
0.080 mg/L
0.005 mg/L
O.O 15 mg/L
15 ug/L
10 ug/L
101 MFL
120,OOO/L
11.4 NTU
41.3 ug/L
5.9 ug/L
1867 ug/L
1.9 ug/L
2.0 ug/L
14.2 ug/L
465 ug/L
14 ug/L
0.3520 mg/L
0.015 + 10%
0.009 mg/L _+10%
1OTto 108fibers/U _
5O,OOO/Lmin.
11 _+1 NTU
0.04 _+10%
0.006 _+10%
2.1 _+10%
0.002 _+10%
2.0 _+10%
0.015 + 10%
0.45 _+20%
0.015 _+20%
0.300 _+10%
1 .Oug/L
2 ug/L
0.17 MFL
8/U
0.41 NTU
0.2 ug/L
0.5 ug/L
0.70 ug/L
0.02 ug/L
0.0005 ug/L
0.5 ug/L
1 .Oug/L
0.70 ug/L
0.0060 mg/L
1 .O ug/L
2 ug/L
0.17 MFL
1/ U
0.24 NTU
0.2 ug/L
0.3 ug/L
0.0588 ug/L
0.02 ug/L
0.0005 ug/L
0.5 ug/L
0.5 ug/L
0.52 ug/L
0.0008 mg/L
93.33
80.8
99.83
99.99
96.4
99.52
91.5
99.96
98.93
99.98
96.47
99.78
94.94
98.4
Test Parameters:
pH = 7.5 _+0.5 unless otherwise
noted.
Flow = 0.5 gpm (1.9 Lpm). Pressure = 60 psig (413.7 kPa).
Temp. = 68°F to 71.6°F (20°C to 22°C). Rated service
capacity
= 100 gallons
(379 liters).
It is essential
that operational,
maintenance,
and filter
replacement
requirements
be carried
out for the product
to
perform
as advertised.
Model TIKBI:
The filter monitor
system measures the amount
of
water that passes through
the filter and alerts you to replace the
filter.
Style
1 - When the filter indicator
reads 10%, order a new filter.
When the filter indicator
reads 0%, it is recommended
that you
replace the filter.
Style 2 - When the filter indicator
light changes
from green to
yellow, order a new filter. When the filter indicator
light changes
from yellow
to red, it is recommended
that you replace the filter.
Use replacement
cartridge
T1 RFKB1, part #9030.
In Canada, use
replacement
cartridge
T1 RFKB1, part #9030B.
2008 suggested
retail price of $41.99
U.S.A./S51.99
Canada.
Prices are subject to
change without
notice.
These contaminants
are not necessarily
in your water supply.
While testing
was performed
under standard
laboratory
conditions,
actual performance
may vary.
The product
is for cold water use only.
Do not use with water that is microbiologically
unsafe or of
unknown
quality
without
adequate
disinfection
before or after the
Average %
Reduction
97.36
99.67
Average %
Reduction
99.33
99.31
96.53
96.5
96.67
99.94
93.33
80.8
99.83
>99.99
97.89
99.52
95.47
100
98.93
99.98
96.47
99.88
96.27
99.78
system.
Systems
certified
for cyst reduction
may be used on
disinfected
waters that may contain
filterable
cysts.
Refer to the "Warranty"
section
for the Manufacturer's
name,
address
and telephone
number.
Refer to the "Warranty"
section
for the Manufacturer's
limited
warranty.
Application
Guidelines/Water
Supply
Parameters
Water Supply
Water Pressure
30 - 120 psi (207 - 827 kPa)
Water Temperature
33 ° - 100°F (0.6 ° - 37.8°C)
Service
Flow Rate
0.5 gpm (1.9 L/min) @ 60 psi
*Class I particle size: >0.5 to <1 um
**Test requirement is at least 100,000 particles/mL
of AC Fine Test Dust.
ttFibers greater than 10 um in length
€Based on the use of Cryptosporidium
parvum oocysts
® NSF is a registered trademark of NSF International.
23

Advertisement

Table of Contents
loading

Table of Contents