Performance Data Sheet - Kenmore 106.5942 series Use & Care Manual

Table of Contents

Advertisement

Available languages

Available languages

PERFORMANCE DATA SHEET
Base Grille Water Filtration System
Model TIKB2/TIRFKB2
Capacity
200 Gallons (757 Liters) without
Filter Indicator
Light
System tested
and certified
by NSF International
against
NSF/ANSI
Standard
42 for the reduction
of Chlorine
Taste and Odor, Particulate
Class I*; and against
NSF/ANSI
Standard
53 for the
reduction
of Lead, Mercury, Atrazine,
Benzene,
Toxaphene,
O-Dichlorobenzene,
Cysts, Turbidity,
Asbestos,
Lindane,
Tetrachloroethylene,
Endrin, Alachlor,
Chlorobenzene
and Ethylbenzene.
This system
has been tested
according
to NSF/ANSI
Standards
42 and 53 for the reduction
of the substances
listed
below.
The
concentration
of the indicated
substances
in water
entering
the system
was reduced
to a concentration
less than
or equal
to the
permissible
limit
for water
leaving
the system,
as specified
in NSF/ANSI
Standards
42 and 53.
Substance
Reduction
NSF Reduction
Average
Influent
Challenge
Maximum
Average
Minimum %
Average %
Aesthetic
Effects
Requirements
Influent
Concentration
Effluent
Effluent
Reduction
Reduction
Chlorine Taste/Odor
50% reduction
2.0 mg/L
2.0 mg/L + 10%
0.08 mg/L
**
2.0 mg/L
95.93
97.36
Particulate Class I*
85% reduction
3533333#/mL
At east 10,000 part c es/mL
22000 #/mL
11567 #/mL
99.38
99.67
Contaminant
NSF Reduction
Average
Influent
Challenge
Maximum
Average
Minimum %
Average %
Reduction
Requirements
Influent
Concentration
Effluent
Effluent
Reduction
Reduction
Lead: @ pH 6.5
0.010 mg/L
150 ug/L
0.15 mg/L + 10%
1.0 ug/L
1 ug/L
99.33
99.33
Lead: @ pH 8.5
0.010 mg/L
157 ug/L
0.15 mg/L _+10%
2.0 ug/L
1.08 ug/L
98.72
99.31
Mercury: @ pH 6.5
0.002 mg/L
0.0058 mg/L
0.006 mg/L + 10%
0.0002 mg/L
0.0002 mg/L
96.53
96.53
Mercury: @ pH 8.5
0.002 mg/L
0.0057 mg/L
0.006 mg/L _+10%
0.0002 mg/L
0.0002 mg/L
96.5
96.5
Benzene
0.005 mg/L
15 ug/L
0.015 mg/L _+10%
0.5 ug/L
0.5 ug/L
96.67
96.67
O-Dichlorobenzene
0.6 mg/L
1750 ug/L
1.8 _+10%
1.0 ug/L
1.0 ug/L
99.94
99.94
Toxaphene
0.003 mg/L
15 ug/L
0.015 _+10%
1.0 ug/L
1.0 ug/L
93.33
93.33
Atrazine
0.003 mg/L
10 ug/L
0.009 mg/L _+10%
2 ug/L
2 ug/L
80.8
80.8
Asbestos
99%
101 MFL
107to 108fibers/U t
0.17 MFL
0.17 MFL
99.83
99.83
Live Cysts _
>99.95%
120,000/L
50,000/L min.
8/U
1/U
99.99
>99.99
Turbidity
0.5 NTU
11.4 NTU
11 _+1 NTU
0.41 NTU
0.24 NTU
96.4
97.89
Alachlor
0.002 mg/L
41.3 ug/L
0.04 _+10%
0.2 ug/L
0.2 ug/L
99.52
99.52
Endrin
0.002 mg/L
5.9 ug/L
0.006 _+10%
0.5 ug/L
0.3 ug/L
91.5
95.47
Ethylbenzene
0.7 mg/L
1867 ug/L
2.1 _+10%
0.70 ug/L
0.0588 ug/L
99.96
100
Lindane
0.002 mg/L
1.9 ug/L
0.002 _+10%
0.02 ug/L
0.02 ug/L
98.93
98.93
Chlorobenzene
0.6 mg/L
2.0 ug/L
2.0 _+10%
0.0005 ug/L
0.0005 ug/L
99.98
99.98
Tetrachloroethylene
0.005 mg/L
14.2 ug/L
0.015 _+10%
0.5 ug/L
0.5 ug/L
96.47
96.47
Test Parameters: pH : 7.5 4- 0.5 unless otherwise noted. Flow = 0.5 gpm (1.9 Lpm). Pressure = 60 psig (413.7 kPa).
Temp. = 68°F to 71.6°F (20°C to 22°C). Rated service capacity
= 200 gallons (757 liters).
It is essential that operational,
maintenance,
and filter
replacement
requirements
be carried out for the product to
perform
as advertised.
Model T1KB2: Change the water filter cartridge
every
6 months. If the water flow to the water dispenser or ice
maker decreases noticeably
before 6 months have passed,
replace the water filter cartridge
more often.
Use replacement
cartridge
T1RFKB2, part #9030.
2011 suggested retail price of $59.99 U.S.A./S71.99
Canada.
Prices are subject to change without notice.
These contaminants
are not necessarily
in your
water
supply.
While
testing
was performed
under
standard
laboratory
conditions,
actual
performance
may
vary.
The product
is for cold
water
use only.
Do not use with
water
that is microbiologically
unsafe
or of
unknown
quality
without
adequate
disinfection
before
or
after
the system.
Systems
certified
for cyst reduction
may be
used on disinfected
waters
that may
contain
filterable
cysts.
Refer to the "Warranty"
section for the Manufacturer's
name, address and telephone number.
Refer to the "Warranty"
section for the Manufacturer's
limited warranty.
Application
Guidelines/Water
Supply
Parameters
Water
Supply
City or Well
Water
Pressure
30 - 120 psi (207
- 827
kPa)
Water
Temperature
33 ° - IO0°F
(0.6 ° - 37.8°C)
Service
Flow Rate
0.5 gpm
(1.9 L/min)
@ 60 psi
*Class I particle size: >0.5 to <1 um
**Test requirement
is at least 100,000 particles/mL
of AC Fine Test Dust.
ttFibers greater than 10 um in length
_Based on the use of Cryptosporidium
parvum oocysts
® NSF is a registered trademark
of NSF International.
28

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

106.5943 series106.5110 series

Table of Contents