Preparation Before Sewing; Installing The Needle; 2. Removing The Bobbin Case - Consew 206RBL-18 Operating Instructions & Parts Book

Table of Contents

Advertisement

5. PREPARATION BEFORE SEWING
5-1. Installing the needle
A
CAUTION
A •
Turn off the power switch before installing the needle. The motor will keep turning even after the
f..:t:),.
power is switched
off
as a result of the motor's inertia. Wait until the motor stops fully before
starting work. The machine may operate if the treadle is pressed by mistake, which could result in
injury.
long groove - - . ;
5-2. Removing the bobbin case
1. Turn the machine pulley toward you to move the
needle bar to its highest position.
2. Loosen the screw
O.
3. Holding the needle
e
with its long groove facing
left, insert all the way into the needle bar.
4. Tighten the screw
O.
A
CAUTION
A •
Turn
off
the power supply before removing the bobbin case. The motor will keep turning even after
ill
the power is switched
off
as a result of the motor's inertia. Wait until the motor stops fully before
starting work. The machine may operate if the treadle is pressed by mistake, which could result in
injury.
...
-
..
., CDo
.......
1. Open the bed slide.
2. Pull the latch
0
of the bobbin case upward and
then remove the bobbin case.
3. The bobbin
e
will come out when the latch
0
is
released .

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents