Advertisement

Kodiak 1200 FPI & Kodiak 1700 FPI
OWNER`S MANUAL
O- T L
Tested &
Portland
Listed By
Oregon USA
C
US
OMNI-Test Laboratories, Inc,
Report # 268-S-05-2, 268-S-06c-2
Report # 268-S-06b-2
Version Française: www.enviro.com/fr.html
W O O D S T O V E I N S E R T
PLEASE READ THIS ENTIRE MANUAL BEFORE INSTALLATION AND USE OF THIS
WOOD BURNING ROOM HEATER. FAILURE TO FOLLOW THESE INSTRUCTIONS
COULD RESULT IN PROPERTY DAMAGE, BODILY HARM, OR EVEN DEATH.
CONTACT YOUR BUILDING OR FIRE OFFICIALS ABOUT RESTRICTIONS AND
INSTALLATION INSPECTION REQUIREMENTS IN YOU AREA.
THIS HEATER MEETS THE 2015 U. S. ENVIRONMENTAL PROTECTION AGENCY'S CRIB-
WOOD EMISSION LIMITS FOR WOOD HEATERS SOLD AFTER MAY 15, 2015.
SPECIFIC CONDITIONS THIS HEATER HAS BEEN SHOWN TO DELIVER HEAT AT RATES
RANGING FROM 11,479 TO 34,196 BTU PER HOUR FOR THE 1200 AND FROM 9,425 TO
31,780 BTU PER HOUR FOR THE 1700. THESE STOVES HAVE BEEN CERTIFICATION TESTED
TO STANDARDS UL-1482-11 AND ULC-S627-00. CERTIFICATION TESTING COMPLETED BY
OMNI-TEST LABORATORIES.
INSTALLER: LEAVE THIS MANUAL WITH THE WOOD STOVE.
CONSUMER: RETAIN THIS MANUAL FOR FUTURE REFERENCE.
UNDER
50-2910

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Kodiak 1200 FPI and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Enviro Kodiak 1200 FPI

  • Page 1 Kodiak 1200 FPI & Kodiak 1700 FPI W O O D S T O V E I N S E R T OWNER`S MANUAL PLEASE READ THIS ENTIRE MANUAL BEFORE INSTALLATION AND USE OF THIS WOOD BURNING ROOM HEATER. FAILURE TO FOLLOW THESE INSTRUCTIONS COULD RESULT IN PROPERTY DAMAGE, BODILY HARM, OR EVEN DEATH.
  • Page 2: Table Of Contents

    Table of Contents Safety Precautions..................3 Emissions and Efficiency..................4 Operating Instructions..................5 Building Your Fire.................6 How It Works..................10 Specifications....................11 Air Control..................11 General Specifications................11 Clearances To Combustibles - 1200 KI Insert.........12 Clearances To Combustibles - 1700 KI Insert.........13 Dimensions - 1200 KI Insert..............14 Dimensions - 1700 KI Insert..............15 Installation....................16 Removal From Pallet................16...
  • Page 3: Safety Precautions

    Safety Precautions PLEASE READ THIS ENTIRE MANUAL BEFORE YOU INSTALL AND USE OF YOUR NEW WOOD STOVE. FAILURE TO FOLLOW INSTRUCTIONS MAY RESULT IN PROPERTY DAMAGE, BODILY INJURY OR EVEN DEATH. BE AWARE THAT LOCAL CODES AND REGULATIONS MAY OVERRIDE SOME ITEMS IN THIS MANUAL. PLEASE CHECK WITH YOUR LOCAL BUILDING OR FIRE AUTHORITY.
  • Page 4: Emissions And Efficiency

    1200 odiaK Rates: This manual describes the installation and operation of the Enviro Kodiak 1200 wood heater. This heater meets the 2015 U.S. Environmental Protection Agency’s wood emission limits for wood emission limits sold after May 15, 2015. Under specific test conditions this heater has been shown to deliver heat at rates ranging from 11,500-34,000 Btu/hr.
  • Page 5: Operating Instructions

    Wear protective gloves when handling damaged glass door assembly to prevent personal injury. When the glass door assembly is being transported, it must be wrapped in newsprint and tape and/or a strong plastic bag. Replacement glass must be purchased from an ENVIRO dealer. No substitute materials are allowed.
  • Page 6: Building Your Fire

    Operating Instructions CREOSOTE - ITS FORMATION AND REMOVAL: When wood is burned slowly, it may produce tar and other vapors that, combined with moisture, form creosote. These creosote vapors condense in the relatively cool chimney flue of a slow burning fire and, if ignited, make an extremely hot fire.
  • Page 7 Operating Instructions 2. Building/Maintaining a Fire: a) Open the primary air slide by pulling it all the way to the right. b) Place a base of crumpled uncolored paper in the bottom of the stove. Lay pieces of kindling on top of the newspaper and light it.
  • Page 8 Operating Instructions Helpful Hints Worth Repeating 1. Helpful advice on the correct way to start your fire. a) You will need small pieces of dry wood, called kindling, and paper. Use only newspaper or paper that has not been coated or had other materials glued or applied to it. Never use coated (typically advertising flyers) or coloured paper.
  • Page 9 Operating Instructions 5. Why won’t my fire light? Damp or wet wood and a poor draft are the main reasons for poor results in starting a fire. Always use dry, seasoned wood for your fire. Even wood dried for two years will be difficult to ignite if it has become wet from rain.
  • Page 10: How It Works

    Operating Instructions orKs Exhaust Smoke Convection Heat " Ceramic baffle; reflects heat down to burn the particles Primary air; window in the smoke. air wash (cooler air to keep the glass clean). Secondary air tubes; creates a second burn on the particles in the smoke for a more efficient &...
  • Page 11: Specifications

    To increase your air pull the rod out, and to decrease push the rod in. All Enviro wood stoves have a secondary air that flows through the stainless tubes at the top of the firebox just below the baffles.
  • Page 12: Clearances To Combustibles - 1200 Ki Insert

    Specifications - 1200 Ki i lEarancEs ombustiblEs nsErt Table 2: 1200 KI Insert Clearance to Combustibles. A Minimum clearance to an unshielded side wall 10” (254 mm) B Minimum clearance to an unshielded 8” (203 21” (533 mm) mm) mantel C Minimum top facing (protruding ¾”...
  • Page 13: Clearances To Combustibles - 1700 Ki Insert

    Specifications - 1700 Ki i lEarancEs ombustiblEs nsErt Table 5: 1700 KI Insert Clearance to Combustibles. Minimum clearance to an unshielded side wall 10” (254 mm) Minimum clearance to an unshielded 8” (203 24” (610 mm) mm) mantel Minimum top facing (protruding ¾” 19½”...
  • Page 14: Dimensions - 1200 Ki Insert

    Specifications - 1200 Ki i imEnsions nsErt Figure 5: 1200 KI Insert Dimensions.
  • Page 15: Dimensions - 1700 Ki Insert

    Specifications - 1700 Ki i imEnsions nsErt Figure 6: 1700 KI Insert Dimensions.
  • Page 16: Installation

    Installation Emoval allEt • Remove the bricks from the unit before starting. • Remove the two (2) lag bolts (shown in Figure 7) that secure the unit to the pallet from inside the firebox. Note: Before the bricks are re-installed, rivets (Figure 8) must be placed in the two holes where the lag bolts were removed in the firebox .
  • Page 17: Masonry Fireplace Installation

    Installation asonry irEplacE nstallation Installation must be completed by a certified professional in order for warranty to be valid. Install only in a masonry fireplace with a good-condition chimney at least 15 ft (4.6 m) high, both of which have been constructed in accordance with the building code. Refer to Tables 4 and 7 for minimum masonry fireplace dimensions.
  • Page 18 Installation The flue collar is removable for installations into fireplaces with low openings. a) Remove the rear two (2) secondary air tube and C-Cast Ceramic Baffles, if installed (see c-c eraMic affLe ). Remove the secondary air nstaLLation tubes by placing a screwdriver (any style except flat head) into one of the air holes and tapping it with a hammer/mallet to the left.
  • Page 19 Installation Figure 15: Removable flue collar in place. 4. Screw or nail the provided metal plate with the wording “THIS FIREPLACE HAS BEEN ALTERED TO ACCOMMODATE A FIREPLACE INSERT AND SHOULD BE INSPECTED BY A QUALIFIED PERSON PRIOR TO THE RE-USE AS A CONVENTIONAL FIREPLACE.”...
  • Page 20: Installation Using A Block-Off Plate For Usa Only

    Installation usa o nstallation sinG locK latE If this unit is to be installed into a masonry fireplace or a zero-clearance fireplace with a direct connection you must install a non-combustible seal-off device such as a block-off plate or damper adapter. By installing a block-off plate you seal the chimney, ensuring that no smoke enters the home and sealing the chimney to encourage draft.
  • Page 21 Installation fireplace and sheet metal screws on a zero-clearance fireplace (screws need only be long enough to penetrate the first layer of metal). Mantel 6. Insulate the block-off plate Stainless steel chimney using high - temperature Damper must connector must extend fiberglass insulation be removed...
  • Page 22: Model 1200 Ki Brick Placement & Tube Locations

    Installation 1200 Ki b & t odEl ricK lacEmEnt ocations COMPLETE THE STOVE AND SMOKE PIPE INSTALLATION BEFORE PLACING THESE BRICKS. Tube E Tube D Tube A 1. Place the three (3) full size bricks along each side of the firebox and one (1) full size brick on either side of the back of the firebox.
  • Page 23: Model 1700 Ki Brick Placement & Tube Locations

    Installation 1700 Ki b & t odEl ricK lacEmEnt ocations COMPLETE THE STOVE AND SMOKE PIPE INSTALLATION BEFORE PLACING THESE BRICKS. Tube C Tube B 1. Place the four (4) full size Tube A bricks along each side of the firebox and one (1) full size brick on either side of the back of the firebox.
  • Page 24: C-Cast Ceramic Baffle Installation

    Installation Eramic afflE nstallation 1. Slide the right C-Cast Ceramic Baffle in over the secondary air tubes at the top of the firebox. The tab must be on the top and pointing towards the center and the smooth side is to face down. 2.
  • Page 25: Fan Wiring Diagrams

    KI FAN WIRING DIAGRAM Installation WIRE B (Black) - 12” Black Fan Temp Sensor WIRE C (Black) - 14” + 14” Rocker Switch Black Black WIRE A (Black) - 26” AUTO White MANUAL Ground Power Supply Controller (Rheostat) Figure 25: KI Fan Wiring Diagram. Emoval The KI Insert comes with the fan assembled and installed in the left shroud.
  • Page 26: Removal Of Top

    Installation Emoval 1. To remove the top from the unit lift up and pull forward. Figure 27: Removal of Top. nstallation urround anEl 1. You will need to remove the top as shown above before installing the surround panel. 2. Once the top has been removed slide the surround panel over the unit.
  • Page 27: Rating Label

    Rating Label DO NOT REMOVE THIS LABEL / NE PAS ENLEVER CETTE ÉTIQUETTE Serial No. / No. De Serié: Tested & LISTED SOLID FUEL SPACE HEATER / IDENTIFIE COMME UN FOYER A COMBUSTIBLE SOLIDE Listed By Boston 1200 FPI Venice 1200 FPI 1200 KI FPI Boston 1200 FS Kodiak 1200 FS...
  • Page 28: Parts List

    EC-042 Heyco Strain Relief EC-044 Wood Door Gasket EF-168 Glass with Tape 10-000 Enviro Logo Gel Decal 50-322 1200 & 1700 Front Secondary Air Tube A 50-1099 1700 Rear Secondary Air Tube C 50-1100 1700 Middle Secondary Air Tube B...
  • Page 29: Parts Diagram

    Parts Diagram...
  • Page 30: Notes

    Notes...
  • Page 31: Warranty

    Exclusions conditions herein set forth, this product against defects in material and workmanship An expanded list of exclusions is available at www.enviro.com/help/warranty.html during the specified warranty period starting from the date of original purchase at retail. This warranty does not cover: In the event of a defect of material or workmanship during the specified warranty period, ƒ...
  • Page 32: Installation Data Sheet

    NAME OF INSTALLER: MODEL:___________________________________ SERIAL NUMBER:___________________________ _________________________________________ DATE OF PURCHASE: ______________ (dd/mm/yyyy) ADDRESS: DATE OF INSTALLATION:___________ (dd/mm/yyyy) _________________________________________ INSTALLER’S SIGNATURE: _________________________________________ _________________________________________ _________________________________________ PHONE:___________________________________ MANUFACTURED BY: SHERWOOD INDUSTRIES LTD. 6782 OLDFIELD RD. SAANICHTON, BC, CANADA V8M 2A3 www.enviro.com October 28, 2015 C-14577...

This manual is also suitable for:

Kodiak 1700 fpi

Table of Contents