Enviro 1200 Insert Owner's Manual
Hide thumbs Also See for 1200 Insert:
Table of Contents

Advertisement

SHERWOOD INDUSTRIES IS AN ENVIRONMENTALLY RESPONSIBLE COMPANY. THIS MANUAL IS PRINTED ON RECYCLED PAPER.
PLEASE KEEP THESE INSTRUCTIONS FOR FUTURE REFERENCE
OWNER'S MANUAL
Models: 1200 & 1700 Insert and 1200 & 1700 Fireplace Freestanding
INSTALLER: Leave this manual with the wood stove.
CONSUMER: Retain this manual for future reference.
Contact your local building or fire officials, or the authority having jurisdiction
about restrictions and installation inspection requirements in your area.
PLEASE READ THIS ENTIRE MANUAL BEFORE INSTALLATION AND USE OF THIS WOOD
BURNING ROOM HEATER. FAILURE TO FOLLOW THESE INSTRUCTIONS COULD RESULT
IN PROPERTY DAMAGE, BODILY INJURY OR EVEN DEATH.
O- T L
Tested &
Beaverton
Listed By
Oregon USA
C
OMNI-Test Laboratories, Inc,
Kodiak
B Y : S H E R W O O D I N D U S T R I E S L T D
This heater meets the U. S. Environmental Protection Agencies
emission limits for wood heaters sold after July 1st, 1990.
Under specific conditions this heater has been shown to deliver
heat at rates ranging from 11,479 to 34,196 BTU per hour for
the 1200 and from 9,425 to 31,780 BTU per hour for the 1700.

Wood Stove

50-1040

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 1200 Insert and is the answer not in the manual?

Questions and answers

Summary of Contents for Enviro 1200 Insert

  • Page 1: Wood Stove

    SHERWOOD INDUSTRIES IS AN ENVIRONMENTALLY RESPONSIBLE COMPANY. THIS MANUAL IS PRINTED ON RECYCLED PAPER. Kodiak PLEASE KEEP THESE INSTRUCTIONS FOR FUTURE REFERENCE Wood Stove B Y : S H E R W O O D I N D U S T R I E S L T D OWNER’S MANUAL Models: 1200 &...
  • Page 2: Table Of Contents

    Air Control.....................9 How It Works..................10 Specifications....................11 1200 Specifications................11 1700 Specifications:................12 Clearances To Combustibles - 1200 Insert..........13 Clearances To Combustibles - 1700 Insert..........14 Clearances To Combustibles - 1200 Freestanding........15 Clearances To Combustibles - 1700 Freestanding........16 Dimensions - 1200 Insert..............17 Dimensions - 1200 Insert..............18 Dimensions - 1200 Freestanding............19...
  • Page 3: Safety Precautions

    Safety Precautions FOR SAFE INSTALLATION AND OPERATION OF YOUR “ENVIRO” WOOD STOVE, PLEASE CAREFULLY READ THE FOLLOWING INFORMATION: ● Please read this entire manual before you install and use your new woodstove. Failure to follow instructions may result in property damage, bodily injury or even death. Be aware that local Codes and Regulations may override some items in this manual.
  • Page 4: Operating Instructions

    Operating Instructions FIRST START When first installed, the chimney, firebricks and steel are cold and it usually takes several hours on a fairly high burn for them to become hot and dry enough for the stove to function well. We recommend during the unit’s first burn that a door and window are opened to vent the smoke and fumes created from the unit’s paint curing.
  • Page 5 Wear gloves when handling damaged glass door assembly to prevent personal injury. When the glass door assembly is being transported, it must be wrapped in newsprint and tape and/or a strong plastic bag. The glass must be purchased from an ENVIRO dealer. No substitute materials are allowed. CLEANING THE PLATED SURFACES: Painted faces should be wiped with a damp cloth periodically.
  • Page 6: Building Your Fire

    Operating Instructions MAINTENANCE: At the end of each heating season clean the chimney and the smoke pipe. If soot has accumulated above the top baffle bricks, remove, clean, and then replace them. If the secondary air tube is badly eroded, replace it.
  • Page 7 Operating Instructions c) DO NOT OVERFIRE. If the heater or chimney connector glows, you are overfiring. d) CAUTION: DO NOT PLACE FUEL WITHIN SPACE HEATER INSTALLATION CLEARANCES OR WITHIN THE SPACE REQUIRED FOR CHARGING AND ASH REMOVAL. 4. For Maximum Efficiency: When the stove is hot, load it fully to the top of the door opening and burn at medium low settings.
  • Page 8 Operating Instructions length for the logs used in the 1200 would be about 16“ (381 mm) but it can burn pieces up to 18” long. Ideal length for the logs used in the 1700 would be about 18“ (381 mm) but it can burn pieces up to 20” long logs.
  • Page 9: Air Control

    Operating Instructions a) Air supply – Inside the home, normal household appliances such as clothes dryers and forced-air furnaces compete for air, resulting in air starvation to the fire. This creates a condition in the house known as negative pressure. When a house experiences negative pressure, the combustion gases can be drawn from the chimney and into the house.
  • Page 10: How It Works

    Operating Instructions ORKS Smoke " Ceramic baffle; Primary air; reflects heat down window airwash. to burn up smoke. Secondary air tubes; Pilot air. creates a secondary burn on the particles in the smoke. Dry seasoned wood Slider plate; used for air flow control. Intake air.
  • Page 11: Specifications

    Specifications 1200 S PECIFICATIONS Table 1: 1200 General Information. Model 1200 Freestanding 1200 Insert Flat Top Step Top 273⁄4” x 211⁄2” Width x Depth 25” x 22 ” (635 mm x 570 mm) (705 mm x 546 mm) 28 1⁄4”...
  • Page 12: 1700 Specifications

    Specifications 1700 S PECIFICATIONS Table 2: 1700 General Information. Model 1700 Freestanding 1700 Insert Flat Top Step Top 273⁄4” x 26” Width x Depth 25” x 26 ” (635 mm x 684 mm) (705 mm x 660 mm) 28 1⁄4” 31 1⁄4”...
  • Page 13: Clearances To Combustibles - 1200 Insert

    Specifications - 1200 I LEARANCES OMBUSTIBLES NSERT Table 3: 1200 Insert Clearance to Combustibles. A Minimum clearance to an unshielded side wall 10” (254 mm) B Minimum clearance to an unshielded 8” (203 21” (533 mm) mm) mantel C Minimum top facing (protruding 3⁄4” [19 mm]) 171⁄2”...
  • Page 14: Clearances To Combustibles - 1700 Insert

    Specifications - 1700 I LEARANCES OMBUSTIBLES NSERT Table 6: 1700 Insert Clearance to Combustibles. Minimum clearance to an unshielded side wall 10” (254 mm) Minimum clearance to an unshielded 8” (203 24” (610 mm) mm) mantel Minimum top facing (protruding 3⁄4” 191⁄2”...
  • Page 15: Clearances To Combustibles - 1200 Freestanding

    Specifications - 1200 F LEARANCES OMBUSTIBLES REESTANDING MAINTAIN THESE MINIMUM CLEARANCES TO UNSHIELDED COMBUSTIBLES* �������� ���� � ������ ���� ���� ���� ���� � � � � � � � � � � � ����� � � � � ����� ����� ������...
  • Page 16: Clearances To Combustibles - 1700 Freestanding

    Specifications - 1700 F LEARANCES OMBUSTIBLES REESTANDING MAINTAIN THESE MINIMUM CLEARANCES TO UNSHIELDED COMBUSTIBLES* �������� ���� � ������ ���� ���� ���� ���� � � � � � � � � � � � ����� � � � � ����� ����� ������...
  • Page 17: Dimensions - 1200 Insert

    Min 13 " (337mm) Max 14 " (380mm) Regular Surround 5" " " (709mm) (127mm) (419mm) Oversized Surround " (709mm) " " (486mm) (525mm) " " (467mm) (484mm) " (497mm) 19" " (482mm) (5mm) " (580mm) Figure 6: 1200 Insert Dimensions.
  • Page 18: Dimensions - 1200 Insert

    Specifications - 1200 I IMENSIONS NSERT " (684mm) " (566mm) " (705mm) " (860mm) " (1171mm) " (630mm) Min. 17 " (452mm) Max. 19 " (495mm) Regular Surround 21" 5" " (709mm) (533mm) (127mm) Oversized Surround " (709mm) " (525mm) "...
  • Page 19: Dimensions - 1200 Freestanding

    Specifications - 1200 F IMENSIONS REESTANDING " 25" (570mm) (635mm) " " " (151mm) (153mm) (419mm) " " " (402mm) (769mm) (252mm) " (760mm) " (718mm) 20" " (508mm) (98mm) 10" (254mm) Legs same height " " (375mm) (619mm) " (670mm) Figure 8: 1200 Freestanding Flat Top Dimensions.
  • Page 20: Dimensions - 1700 Freestanding

    Specifications - 1700 F IMENSIONS REESTANDING 25" (635mm) " " (684mm) (492mm) " 21" " (151mm) (534mm) (153mm) " " (403mm) (252mm) " (769mm) " (718mm) 10" (254mm) Pedestal same height " (586mm) " " " (659mm) (622mm) (98mm) Figure 10: 1700 Freestanding Flat Top Dimensions. "...
  • Page 21: Freestanding Side Dimensions For Fan Kit

    Specifications REESTANDING IMENSIONS �� ������� � � � � � ������� � � � � � ������ �� � � � � ������� Figure 12: 1200 Freestanding with Fan Kit Dimensions. �� ���� ��� � � � � � ���� ��� �...
  • Page 22: Installation

    Installation Please read and understand these instructions before installing pedestal or ash pan and leg option. Failure to follow these instructions carefully could cause personal injury or property damage. All screws are pre-installed on the base of the unit. EMOVAL ALLET •...
  • Page 23: Legs And Ash Pan Installation - Freestanding

    Installation NSTALLATION REESTANDING • Place the unit on the pallet on its back. • Attach pedestal spacer to bottom of the unit, using the supplied screws. • Attach the air channel box to the front of the pedestal spacer using two (2) T-20 screws.
  • Page 24: Modifications For Installation With 191⁄4" (489Mm) High Lintel - Insert

    Installation 191⁄4” (489 ODIFICATIONS NSTALLATION WITH INTEL NSERT The Kodiak has a factory height of 19 ” (497mm) and it can be reduced to 19 ” (484mm) by modifying the unit and the surround panel. Surround Panel: 1. Fasten the Surround Spacer to the inner top surface of the Surround Panel using the four (4) T-20 screws (refer to Figure 19).
  • Page 25: Hearth Protection Examples

    Installation EARTH ROTECTION XAMPLES Table 11: Examples of Hearth Pad Sizing Using Clearances From Tables 9 &10 (refer to Figures 22 & 23). Canada 1200 1700 1200 1700 (A) Minimum Width 401⁄2” (1028mm) 361⁄2” (926mm) 46” 501⁄2” 42” 461⁄2” (B) Minimum Depth (1168mm) (1283mm) (1067mm)
  • Page 26 Installation Optional USA 6" (152mm) Coverage CND 8" (203mm) USA 6" (152mm) CND 8" (203mm) USA 6" (152mm) CND 8" (203mm) USA 6" Door Opening (152mm) CND 8" (203mm) USA 16" (406mm) Door Opening CND 18" (457mm) Optional Optional Coverage Coverage USA 16"...
  • Page 27 Installation...
  • Page 28: Outside Air Kit

    Installation UTSIDE It is mandatory to use outside air for installations in mobile homes. ���� �� �������� A 4” (10.2 cm) fresh air adaptor kit is available. This adaptor can be installed either on the back pedestal or through the floor under the pedestal.
  • Page 29: Chimney Installation Through Wall

    Installation HIMNEY NSTALLATION HROUGH Here are four (4) methods of combustible wall chimney connector pass-throughs. Information was provided from NFPA 211. Minimum chimney clearance to brick Method A. 12” (304.8 mm) Clearance to Combustible Wall Member: and combustibles 2 inches (50.8 mm) Using a minimum thickness 3.5”...
  • Page 30: Installation Of A Listed, Factory Built Chimney - Freestanding

    Installation NSTALLATION OF ISTED ACTORY UILT HIMNEY REESTANDING This is a generic set of instructions; always follow the chimney manufacturer’s instructions explicitly. Also refer to “R ”. ECOMMENDED EIGHTS Set floor protector and stove in location in accordance with the “C - 1200 LEARANCES OMBUSTIBLES...
  • Page 31 Installation and in any area within 10 feet (304.8 cm) of the roof ridge, the chimney must be 2 feet Storm Collar Roof radiation (60.9 cm) above the ridge. Roof flashing shield (if required) Refer to Figure 30. Roof Note: Increasing the chimney Insulated chimney height above the roof may help your unit to draft better.
  • Page 32 Installation ASONRY HIMNEY NSTALLATION REESTANDING DO NOT CONNECT THIS UNIT TO A CHIMNEY FLUE SERVING ANOTHER APPLIANCE. A non-combustible floor protector is required under all freestanding units; refer to “C LEARANCES - 1200 F ” or “C - 1700 F ”.
  • Page 33: Masonry Fireplace Installation - Freestanding

    Installation ASONRY IREPLACE NSTALLATION REESTANDING Unless you are experienced, we recommend installation by your dealer or a professional Rain Cap installer. Steel Plate or Flashing Chimney Support and Clamp Many venting manufacturers have listed kits available to connect a stove to a masonry fireplace. Always follow the vent manufacturer’s installation Rigid Stainless Steel Liner...
  • Page 34 Installation These connectors must be installed in accordance with the manufacturer’s instructions. Use only Spark arrestor cap specified components. The chimney and pipe must extend at least 10 feet (2.4 m) above the stove and Roof flashing At least 3 feet (0.9 m) above the highest point of the roof. 3 feet (914 mm) Install a rain cap with spark arrestor at the top that Roof...
  • Page 35: Masonry Fireplace Installation - Insert

    Installation ASONRY IREPLACE NSTALLATION NSERT Unless you are experienced, we recommend installation by your dealer or a professional installer. It is recommended that you install the decorative plates (if purchased) into the shrouds before installing the unit. Refer to “I ”.
  • Page 36 Installation flue collar removable installations into fireplaces with low openings. a) Remove the first two (2) front secondary air tube and ceramic baffles, if installed (see C ERAMIC AFFLE NSTALLATION b) Unscrew the nut on top of the inside of the firebox, using a ”...
  • Page 37: Surround Panel Sealed Installation For Usa Only - Insert

    Installation Figure 42: Leveling leg. Figure 41: Attaching removable flue. USA O URROUND ANEL EALED NSTALLATION NSERT Before starting this type of installation ����� �� ��� ���� ���� �� ������������ �� refer to I NSTALLATION ASONRY IREPLACE ��������� ���� ������� ���� � ������� additional NSTALLATION NSERT...
  • Page 38: Installation Using A Block-Off Plate For Usa Only - Insert

    Installation USA O NSTALLATION SING LOCK LATE NSERT If this unit is to be installed into a masonry fireplace or a zero-clearance fireplace with a direct connection you must install a non-combustible seal-off device such as a block-off plate or damper adapter. By installing a block-off plate you seal the chimney, ensuring that no smoke enters the home and sealing the chimney to encourage draft.
  • Page 39 Installation 5. Mount the block-off plate using masonry screws in a masonry fireplace and sheet metal screws on a zero- clearance fireplace (screws Mantel need only be long enough to penetrate the first layer of Stainless steel chimney metal). Damper must connector must extend be removed 12"...
  • Page 40: Model 1200 Brick Placement & Tube Locations

    Installation 1200 B & T ODEL RICK LACEMENT OCATIONS COMPLETE THE STOVE AND SMOKE PIPE INSTALLATION BEFORE PLACING THESE BRICKS. Tube E Tube D Tube A 1. Place the three (3) full size bricks along each side of the firebox and one (1) full size brick on either side of the back of the firebox.
  • Page 41: Model 1700 Brick Placement & Tube Locations

    Installation 1700 B & T ODEL RICK LACEMENT OCATIONS COMPLETE THE STOVE AND SMOKE PIPE INSTALLATION BEFORE PLACING THESE BRICKS. Tube C Tube B 1. Place the four (4) full size Tube A bricks along each side of the firebox and one (1) full size brick on either side of the back of the firebox.
  • Page 42: Door Installation

    Installation NSTALLATION Please inspect all components for damage. If damage has occurred, please contact the courier company, dealer, or distributor and have components repaired or replaced before installation. Remove the door from the packaging. Inspect the door assembly for damage. 1.
  • Page 43: Ceramic Baffle Installation

    Installation ERAMIC AFFLE NSTALLATION 1. Remove the front secondary air tube by placing a screwdriver (any style except flat head) into one of the air holes and tapping it with a hammer/mallet to the left. Step 1 is only required on the insert models.
  • Page 44 Installation DO oil the fan bearings regularly. DO NOT cut or remove the grounding prong from the plug. DO NOT route the power cord beneath the heater. WARNING: This appliance is equipped with a three-prong (grounding) plug for your protection against shock hazard and should be plugged into a properly grounded three-prong receptacle.
  • Page 45: Optional Fan Installation - Freestanding

    Installation PTIONAL NSTALLATION REESTANDING Refer to F before installing your optional fan IRING IAGRAM kit. 1. Remove the fan assembly from the box and inspect for any damage to the assembly. If damage is noticed call your dealer, distributor or courier company and have components replaced before installing kit.
  • Page 46: Removal Of The Shrouds - Insert

    Installation EMOVAL HROUDS NSERT 1. If the surround panel is installed, remove it by lifting the panel straight up then out. 2. For the right shroud, twist the handle on the air control clockwise to remove it from the rod. 3.
  • Page 47: Installation Of The Surround Panel - Insert

    Installation NSTALLATION URROUND ANEL NSERT Installation of Trim: The trim set for your surround panel must be installed before installing the surround panel onto the unit, if not already done. 1. Attach one side trim to the top trim, using a corner bracket (see Figure 60) to secure pieces together.
  • Page 48: Parts List

    Parts List Referance # Description Part # 120°F (49°C) Ceramic Fan Temperature Sensor EC-001 FPI Fan Controller - 115V EC-039 Fan Controller Knob EC-040 Domestic power cord - 115V EC-042 1200 & 1700 Freestanding Convection Blower - 115V EC-069 Door Gasket - 7 feet (2.13m) EF-168 Fresh Air Kit EF-186...
  • Page 49 Parts List Referance # Description Part # Pumice Bricks - 41⁄2” X 41⁄2” (114mm x 114mm) 50-1106 1200 & 1700 Ash Dump Cover 50-1120 Door Handle Assembly (Rod, Cast Latch, Brass Spring) 50-1121 Wood Door Glass Retainer Kit (With Screws) 50-1122 1200 Freestanding Flat Top Left Side Cabinet 50-1123...
  • Page 50: Parts Diagram - Freestanding

    Parts Diagram - Freestanding...
  • Page 51: Parts Diagram - Pedestals & Legs

    Parts Diagram - Pedestals & Legs...
  • Page 52: Parts Diagram - Fireplace Insert

    Parts Diagram - Fireplace Insert Common parts are shown in Parts Diagram - Freestanding.
  • Page 53: Warranty

    Industries, our commitment to the highest level of quality and customer service is the most important thing we do. Each Enviro stove is built on a tradition of using only the finest materials and is backed by our Exclusive Lifetime Limited Warranty to the original purchaser. With Enviro, you’re not just buying a stove, you’re buying a company with years of unequalled performance and quality.
  • Page 54 If you are not satisfied with the service provided by the Enviro dealer, write to Sherwood Industries Ltd. at the address listed on the last page of the Owner’s Manual. Include the date you bought the product and a description of the problem.
  • Page 55 If the stove is used for commercial purposes, it is excluded from the Limited Warranty. 23. No dealer, distributor, or similar person has the authority to represent or warrant Enviro products beyond the terms contained within the Limited Warranty. Sherwood Industries Ltd. assumes no liability for such warranties or representations.
  • Page 56: Installation Data Sheet

    NAME OF INSTALLER: MODEL:___________________________________ SERIAL NUMBER:___________________________ _________________________________________ DATE OF PURCHASE: ______________ (dd/mm/yyyy) ADDRESS: DATE OF INSTALLATION:___________ (dd/mm/yyyy) _________________________________________ INSTALLER’S SIGNATURE: _________________________________________ _________________________________________ _________________________________________ PHONE:___________________________________ MANUFACTURED BY: SHERWOOD INDUSTRIES LTD. 6782 OLDFIELD RD. SAANICHTON, BC, CANADA V8M 2A3 www.enviro.com July 25, 2007 C-11414...