Limiting The Control Range - oventrop Uni LH Installation Instructions Manual

Table of Contents

Advertisement

Available languages

Available languages

Limiting the control range

The control range of the thermostat can be limited with the
clips attached to the inner side of the handgrip. The clips
can only be inserted on the inner side of the handgrip. The
two bridges of a clip have each to be inserted into two
grooves of the inner framework.
E.g.: Limiting a control range to a minimum of 16 °C (fi-
gure "2") and a maximum of 24 °C (figure "4") (e.g. for li-
ving rooms, old peoples' homes).
1
Indicator mark
Calibration mark
Sensor casing
2
3
4
6
Photo 1: Remove the hand-
grip with the tool (item no.
198 91 00) or with a pin,
e.g. with the push button of
a pen. Insert the tool/pin in
the hole provided on the lo-
wer side of the thermostat.
By turning the handgrip to
the shut-off position, it is
easily removed (compare
photo 16).
Photo 2: After having re-
moved the handgrip: Turn
the sensor casing to the left
until the calibration mark
(bore or white stroke) is in
line with the indicator mark.
Photo 3: On the inner side of
the handgrip you will find
two clips in the "parking"
position. They should be
removed by sliding to the
outside. (When not in use,
the clips may of course be
put back in the "parking"
position.)
Photo 4: To limit the mini-
mum control range, e.g. at
figure "2" (equals approx.
16 °C), one clip should be
fitted into the groove im-
mediately before figure "2"
as illustrated.
(The groove directly oppo-
site figure "2" thus remains
free.)
5
6
7
Photo 5: To limit the maxi-
mum control range, e.g. at
figure "4" (equals approx.
24°C), the second clip
should be fitted into the
groove immediately after fi-
gure "4". (The groove di-
rectly opposite figure "4"
thus remains free.).
Photo 6: Replace the hand-
grip so that figure "3" is in
line with the indicator mark.
Photo 7: Push down hand-
grip with hand to secure.
The control range of the
thermostat is now limited
and you can only set values
between figure "2" and "4"
(approx. 16 °C – 24 °C).

Advertisement