Summary of Contents for Skyrc S60

  • Page 1 AC Balance Charger / Discharger SkyRC Technology Co., Ltd. 2015 Version 1.0...
  • Page 2: Table Of Contents

    TABLE OF CONTENTS INTRODUCTION SPECIAL FEATURES WARNING AND SAFETY NOTES PROGRAM FLOW CHART OPERATION OPERATING PROGRAM CHARGING PROGRAM BATTERY MEMORY SET AND CALL OUT SYSTEM SETTING BATTERY METER BATTERY RESISTANCE METER WARNING AND ERROR MESSAGE USING THE CHARGE CONTROL SOFTWARE “CHARGE MASTER” THE SET CONTAINS SPECIFICATION CONFORMITY DECLARATION...
  • Page 3: Introduction

    Congratulations on your choice of SKYRC S60 AC Input Professional Balance Charger/Discharger. This unit is simple to use, but the operation of a sophisticated automatic charger such as SKYRC S60 does require some knowledge on the part of the user. These operating instructions are designed to ensure that you quickly become familiar with its functions.
  • Page 4 INTRODUCTION Please read this entire operating manual completely and attentively before using this product, as it covers a wide range of information on operating and safety. Or please do use this product in company with a specialist! AC Input Power Port Scroll Through the Main Menu AC 100-240V Stop Any Charge Processes...
  • Page 5: Special Features

    Balancing Individual Cells Battery Discharging During the process of discharging, SkyRC S60 can monitor and balance each cell of the battery individually. Error message will be indicated and the process will be ended automatically if the voltage of any single one cell is abnormal.
  • Page 6 SPECIAL FEATURES Re-Peak Mode of NiMH/NiCd Battery In re-peak charge mode, the charger can peak charge the battery once, twice or three times in a row automatically. This is good for making certain the battery is fully charged. Delta-peak Sensitivity for NiMH/NiCd Delta-peak sensitivity for NiMH/NiCd battery: The automatic charge termination program based on the principle of the Delta-peak voltage detection.
  • Page 7: Warning And Safety Notes

    WARNING AND SAFETY NOTES These warnings and safety notes are particularly important. Please follow the instructions for maximum safety; otherwise the charger and the battery can be damaged or at worst it can cause a fire. Never leave the charger unattended when it is connected to its power supply. If any malfunction is found, TERMINATE THE PROCESS AT ONCE and refer to the operation manual.
  • Page 8 WARNING AND SAFETY NOTES Never attempt to charge or discharge the following types of batteries. A battery pack which consists of different types of cells (including different manufacturers) A battery that is already fully charged or just slightly discharged. Non-rechargeable batteries (Explosion hazard). Batteries that require a different charge technique from NiCd, NiMh, LiPo or Gel cell (Pb, Lead acid).
  • Page 9 WARNING AND SAFETY NOTES Attention should be paid to the connection of lithium battery especially. Do not attempt to disassemble the battery pack arbitrarily. Please get highlighted that lithium battery packs can be wired in parallel and in series. In the parallel connection, the battery s capacity is calculated by multiplying single battery capacity by the number of cells with total voltage stay the same.
  • Page 10: Program Flow Chart

    PROGRAM FLOW CHART START LiPo BALANCE CHG LiPo CHARGE LiPo FAST CHARGE LiPo STORAGE LiPo DISCHARGE BATT/PROGRAM 2.0A 7.4V (2S) 2.0A 7.4V (2S) 2.0A 7.4V (2S) 2.0A 7.4V (2S) 2.0A 7.4V (2S) LiPo BATT ENTER START LiFe BALANCE CHG LiFe CHARGE LiFe FAST CHARGE LiFe STORAGE LiFe DISCHARGE...
  • Page 11: Operation

    OPERATION BATT PROG / STOP Button: It is used to stop the progress or go back to previous step/screen DEC Button: It is used to go through the menus and decrease the parameter value INC Button: It is used to go through the menus and increase the parameter value ENTER / START Button: It is used to enter parameter or store parameter on screen.
  • Page 12: Operating Program

    Take care to maintain correct polarity! (See the wiring diagram below.) This diagram shows the correct way to connect your battery to the SKYRC S60 while charging in the balance charge program mode.
  • Page 13 OPERATING PROGRAM 2. Getting started Locate the flowcharts show the entire programming menu. It is highly recommended to have these flowcharts handy while learning to operate this charger. There are two main ways in which to set the charger. A memory profile is available for setting and storing pertinent information for up to 10 different batteries.
  • Page 14: Various Information During The Process

    OPERATING PROGRAM R shows the number of cells detected by the charger and S is R : 3 S E R S : 3 S E R C O N F I R M ( E N T E R ) the number of cells set by you at the previous screen.
  • Page 15: Charging Program

    OPERATING PROGRAM 8. Program Stop During the charging process, press STOP to stop the charging process. 9. Program Complete When the charging process finishes, an audible sound will be heard. Charging Program Depends on different battery type, the operation programs are different. Batt Operation Description...
  • Page 16: Battery Memory Set And Call Out

    BATTERY MEMORY SET AND CALL OUT The charger can store up to 10 different charge/discharge profiles for your convenience, and the stored profiles can be recalled quickly without having to go through the setup process. When you are willing to alter the parameter value in the program, press START/ENTER to make it blink then change the value with INC or DEC.
  • Page 17 BATTERY MEMORY SET AND CALL OUT S A V E P R O G R A M S A V E . [ B A T T M E M O R Y 1 ] Indicate the battery type and battery cell of the saved profile. L i P o  7 .
  • Page 18: System Setting

    SYSTEM SETTING It will be operated with the default value of the essential user settings when it is powered on for the first time.The screen displays the following information in sequence and the user can change the value of parameter on each screen. When you are willing to alter the parameter value in the program, press START/ENTER to make it blink then change the value with INC or DEC.
  • Page 19 SYSTEM SETTING ITEM SELECTION DESCRIPTION This program is for NiMH/NiCd battery N i M H S e n s i t i v i t y D . P e a k D e f a u l t only. When the charger detects the delta Default: 4mV/Cell peak value reaches the value you set, the 3-15mV/Cell...
  • Page 20: Battery Meter

    BATTERY METER The user can check battery's total voltage, the highest voltage, the lowest voltage and each cell's voltage. Please connect the battery to the charger main battery lead to battery socket and balance wires to balance socket. 4.19 4.15 4.18V 4.15 0.00...
  • Page 21: Battery Resistance Meter

    BATTERY RESISTANCE METER The user can check battery's total resistance, the highest resistance, the lowest resistance and each cell's resistance. Please connect the battery to the charger main battery lead to battery socket and balance wires to balance socket. 0 0 5 0 0 3 0 0 3 m Ω...
  • Page 22: Warning And Error Message

    WARNING AND ERROR MESSAGE In case of an error the screen will display the cause of error and emit an audible sound. Incorrect polarity connected. The battery is interrupted. C O N N E C T E R R O R Thebattery connection is wrong.
  • Page 23: Using The Charge Control Software "Charge Master

    USB cable which is not included in this package. The cable must be terminated on one end with “A” plug and the opposite end is terminated with “micro-B” plug which can connect to charger directly. The “Charge Master” can be download from www.skyrc.com. THESETCONTAINS 1. SKYRC S60 Charger 2.
  • Page 24: Specification

    SPECIFICATION AC Input Voltage : 100-240V Display Type: 2x16 LCD Display Backlight: Blue Case Material: Plastic Controls: Four Buttons Case Size: 112x106x52mm Weight: 310g PC Communications: USB Port for PC Control & Firmware Upgrade External Port: 2-4S Balance Socket-XH, Temperature Probe Socket, Battery Socket, Micro USB Port for PC.
  • Page 25: Conformity Declaration

    CONFORMITY DECLARATION SkyRC S60 satisfy all relevant and mandatory CE directives and FCC Part 15 Subpart B: 2012. For EC directives: The product has been tested to meet the following technical standards: EN 55014-1: Electromagnetic Compatibility - EN 55014-1:2006+ Requirements for household appliances, electric...
  • Page 26: Commonly Used Terms

    COMMONLY USED TERMS Commonly used terms Final charge voltage: the voltage at which the battery's charge limit (capacity limit) is reached. The charge process switches from a high current to a low maintenance rate (trickle charge) at this point. From this point on further high current charging would cause overheating and eventual terminal damage to the pack.
  • Page 27: Warranty And Service

    Liability exclusion This charger is designed and approved exclusively for use with the types of battery stated in this Instruction Manual. SkyRC accepts no liability of any kind if the charger is used for any purpose other than that stated.