Return Air Filters; Operation - Monaco 2002 Diplomat Service Manual

Table of Contents

Advertisement

Appliances
---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------

Return Air Filters

Operation

OM040387.eps
4 • 1 2 0
Clean the return air filters frequently and for the environment for which
they operate. The return air filters are inside the air intake vent covers located
on the motorhome ceiling. Never operate the air conditioner without the return
air filters in place. This may plug the evaporator core with dirt and substantial-
ly affect the performance of the air conditioner.
To Clean:
• Remove the vent cover and filter.
• Wash the filter and cover in warm soapy water. Do not use solvents.
• Rinse the filter and cover thoroughly with fresh water. Allow to dry.
• Reinstall the filter and cover.
The roof air conditioners operate from the comfort control only
under the following conditions:
• 120 Volts AC is supplied from either shore power or the generator.
• The battery cut-off switch is in the ON position and house
batteries are charged.
• The ON/OFF switch is ON at the comfort control.
Zone Selection:
The desired zone selection is the first step in utilizing the comfort
control. Press the ZONE button to select Zone 1 or 2 for programming
purposes. The zone currently in programming will flash while the
other zone display is constant.
Fan Operation:
This mode circulates the interior air by using the roof air conditioners
blower. The fan speed will control the roof air conditioners blower
speed in the following modes: Fan, Cool or Heat Pump.
• Press the mode button repeatedly until FAN is displayed.
• Press the FAN button to select the desired fan speed.
Air Conditioner Operation:
The living room comfort control operates the roof air conditioner functions.
• Select the desired zone by pressing the ZONE button.
• Press the MODE button repeatedly until COOL is displayed.
• Set desired fan speed by pressing the FAN button.
• Set desired cooling temperature by pressing the UP or DOWN buttons.
NOTE: The compressor will engage approximately two min-
utes after blower motor activation. This prevents accidental
compressor activation against high pressure.