The Provisioning Process - VTech ErisTerminal VSP600 Administrator And Provisioning Manual

Hide thumbs Also See for ErisTerminal VSP600:
Table of Contents

Advertisement

The Provisioning Process

The automatic provisioning process is as follows:
1. Check for new or updated configuration files. For file-checking options, see
"Provisioning" on page 60
page
compares its current configuration against the files it finds on the provisioning server.
If provisioning has been triggered by the resync timer expiring or by remote
check-sync, the VSP600 checks for updated files after one minute of inactivity.
2. Download the configuration files.
If any file on the provisioning server has changed, the VSP600 treats it as a new file
and downloads it.
If the provisioning URL specifies a path only with no filename, then by default the
VSP600 looks for and retrieves the following two files:
The <model> variable is the VTech product model: VSP600, for example.
If the provisioning URL specifies both a path and filename, then the VSP600 retrieves
only the configuration file specified.
3. The VSP600 restarts after one minute of inactivity.
During provisioning, the VSP600 reads the configuration file and validates each module
and setting. The VSP600 considers a setting valid if it is:
a valid data type
formatted as a valid setting
within a valid data range
part of a module that passes an integrity check. That is, the module's settings are
consistent and logical. For example, in the "network" module, if DHCP is disabled,
but no static IP address is specified, the module will fail the integrity check and
none of the settings will apply.
Invalid modules or invalid settings are skipped and logged as ERROR messages in the
system log, but will not interrupt the provisioning process. The system log will include the
module parameters that have not been applied. A recognized module with unrecognized
settings will cause all other settings in that module to be skipped.
A successful configuration or firmware update is reported as an INFO message in the
system log.
See
"Configuration File Parameter Guide" on page 77
available for each configuration file setting.
Provisioning Using Configuration Files
and
71. The VSP600 maintains a list of the last loaded provisioning files. The VSP600
General file: <model>.cfg.
MAC-specific file: <model>_<MAC Address>.cfg.
VSP600 Administrator and Provisioning Manual
"Resynchronization: configuration file checking" on
for the options and value ranges
70
Back to Contents

Advertisement

Table of Contents
loading

This manual is also suitable for:

Eristerminal vsp601Eristerminalvsp600

Table of Contents