IBM System x3550 M5 Type 5463 Installation And Service Manual page 572

Table of Contents

Advertisement

816f0008-0a02ffff • 816f000d-0400ffff
816f0008-0a02ffff
[PowerSupplyElementName] has been removed from container
[PhysicalPackageElementName]. (Power Supply 2)
Explanation: This message is for the use case when an implementation has detected a Power Supply has been
removed.
May also be shown as 816f00080a02ffff or 0x816f00080a02ffff
Severity: Info
Alert Category: System - Other
Serviceable: No
CIM Information: Prefix: PLAT and ID: 0085
SNMP Trap ID:
Automatically notify Support: No
User response: No action; information only.
816f0009-1301ffff
[PowerSupplyElementName] has been turned on. (Host Power)
Explanation: This message is for the use case when an implementation has detected a Power Unit that has been
Enabled.
May also be shown as 816f00091301ffff or 0x816f00091301ffff
Severity: Info
Alert Category: System - Power On
Serviceable: No
CIM Information: Prefix: PLAT and ID: 0107
SNMP Trap ID: 24
Automatically notify Support: No
User response: No action; information only.
816f000d-0400ffff
The Drive [StorageVolumeElementName] has been removed from unit
[PhysicalPackageElementName]. (Drive 0)
Explanation: This message is for the use case when an implementation has detected a Drive has been Removed.
May also be shown as 816f000d0400ffff or 0x816f000d0400ffff
Severity: Error
Alert Category: Critical - Hard Disk drive
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0163
SNMP Trap ID: 5
Automatically notify Support: No
User response:
1.
Reseat hard disk drive n.(n = hard disk drive number). Wait 1 minute or more before reinstalling the drive.
2.
Replace the hard disk drive.
3.
Make sure that the disk firmware and RAID controller firmware are at the latest level.
4.
Check the SAS cable.
556