v Full Array Memory Mirroring (FAMM) redundancy
v Hot-swap cooling fans with speed-sensing capability
v Hot-swap hard disk drives
v Integrated Management Module (IMM)
v Memory mirroring and memory sparing support
v Memory error correcting code and parity test
v Memory down sizing (non-mirrored memory). After a restart of the server after
v Menu-driven setup, system configuration, and redundant array of independent
v Microprocessor built-in self-test (BIST), internal error signal monitoring, internal
v Nonmaskable interrupt (NMI) button
v Parity checking on the small computer system interface (SCSI) bus and PCI-E
v Power management: Compliance with Advanced Configuration and Power
v Power-on self-test (POST)
v Predictive Failure Analysis (PFA) alerts on memory, microprocessors, SAS/SATA
v Redundant Ethernet capabilities with failover support
v Redundant hot-swap power supplies and redundant hot-swap fans
v Redundant network interface card (NIC) support
v Remind button to temporarily turn off the system-error LED
v Remote system problem-determination support
v ROM-based diagnostics
v ROM checksums
v Serial Presence Detection (SPD) on memory, VPD on system board, power
v Single-DIMM isolation of excessive correctable error or multi-bit error by the
v Solid state drives
v Standby voltage for system-management features and monitoring
v Startup (boot) from LAN through remote initial program load (RIPL) or dynamic
v System auto-configuring from the configuration menu
v System-error logging (POST and IMM)
v Systems-management monitoring through the Inter-Integrated Circuit (IC)
v Uncorrectable error (UE) detection
v Upgradeable POST, Unified Extensible Firmware Interface (UEFI), diagnostics,
v Vital product data (VPD) on microprocessors, system board, power supplies, and
v Wake on LAN capability
16
IBM System x3550 M5 Type 5463: Installation and Service Guide
the memory controller detected a non-mirrored uncorrectable error and the
memory controller cannot recover operationally, the IMM logs the uncorrectable
error and informs POST. POST logically maps out the memory with the
uncorrectable error, and the server restarts with the remaining installed memory.
disks (RAID) configuration programs
thermal trip signal monitoring, configuration checking, and microprocessor and
voltage regulator module failure identification through light path diagnostics
and PCI buses
Interface (ACPI)
hard disk drives or solid state drives, fans, power supplies, and VRM
supply, and hard disk drive or solid state drive backplanes, microprocessor and
memory expansion tray, and Ethernet cards
Unified Extensible Firmware Interface (UEFI)
host configuration protocol/boot protocol (DHCP/BOOTP)
protocol bus
IMM firmware, and read-only memory (ROM) resident code, locally or over the
LAN
SAS/SATA (hot-swap hard disk drive or solid state drive) backplane