80010902-0701ffff
Numeric sensor [NumericSensorElementName] going high (upper critical) has asserted.
Explanation: This message is for the use case when an implementation has detected an Upper Critical sensor going
high has asserted.
May also be shown as 800109020701ffff or 0x800109020701ffff
Severity: Error
Alert Category: Critical - Voltage
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0494
SNMP Trap ID: 1
Automatically notify Support: Yes
User response: If the specified sensor is Planar 3.3V or Planar 5V, (Trained technician only) replace the system
board. If the specified sensor is Planar 12V, complete the following steps until the problem is solved:
1.
Check power supply n LED.
2.
Remove the failing power supply.
3.
(Trained technician only) Replace the system board. (n = power supply number)
80010b01-0f01ffff
Numeric sensor [NumericSensorElementName] going high (upper non-recoverable) has
asserted. (REAR BP Temp A)
Explanation: This message is for the use case when an implementation has detected an Upper Non-recoverable
sensor going high has asserted.
May also be shown as 80010b010f01ffff or 0x80010b010f01ffff
Severity: Error
Alert Category: Critical - Temperature
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0498
SNMP Trap ID: 0
Automatically notify Support: No
User response:
1.
Reduce the ambient temperature.
2.
Ensure the air baffle is installed correctly.
3.
Check the server airflow. Make sure that nothing is blocking the air from coming into or preventing the air from
exiting the server.
80010902-0701ffff • 80010b01-0f01ffff
Appendix A. Integrated management module 2.1 (IMM2.1) error messages
343