8007021b-0302ffff
Sensor [SensorElementName] has transitioned to critical from a less severe state. (CPU 2
QPILinkErr)
Explanation: This message is for the use case when an implementation has detected a Sensor transitioned to critical
from less severe.
May also be shown as 8007021b0302ffff or 0x8007021b0302ffff
Severity: Error
Alert Category: Critical - Other
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0522
SNMP Trap ID: 50
Automatically notify Support: No
User response:
1.
Check for a server firmware update.
2.
Make sure that the installed microprocessors are compatible.
3.
Make sure the microprocessor 2 expansion board is installed correctly (see Installing the microprocessor 2
expansion board).
4.
(Trained technician only) Replace microprocessor 2.
5.
(Trained technician only) Replace microprocessor 2 expansion board.
80070228-2e01ffff
Sensor [SensorElementName] has transitioned to critical from a less severe state. (IPMB IO
Error)
Explanation: This message is for the use case when an implementation has detected a Sensor transitioned to critical
from less severe.
May also be shown as 800702282e01ffff or 0x800702282e01ffff
Severity: Error
Alert Category: Critical - Other
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0522
SNMP Trap ID: 50
Automatically notify Support: No
User response: None ME Error : ME Flash Error :
8007021b-0302ffff • 80070228-2e01ffff