Allied Telesis AT-DC2552XS Installation Manual

Enterprise core switch
Hide thumbs Also See for AT-DC2552XS:
Table of Contents

Advertisement

Quick Links

AT-DC2552XS/L3
ENTERPRISE CORE SWITCH

Installation Guide

613-002097 Rev. A

Advertisement

Table of Contents
loading

Summary of Contents for Allied Telesis AT-DC2552XS

  • Page 1: Installation Guide

    AT-DC2552XS/L3 ENTERPRISE CORE SWITCH Installation Guide 613-002097 Rev. A...
  • Page 2 Allied Telesis, Inc. has been advised of, known, or should have known, the...
  • Page 3: Electrical Safety And Emissions Standards

    Electrical Safety and Emissions Standards This product meets the following standards. U.S. Federal Communications Commission Radiated Energy Note: This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of FCC Rules.
  • Page 4: Translated Safety Statements

    Translated Safety Statements Important: The indicates that translations of the safety statement are available in the PDF  document “Translated Safety Statements” posted on the Allied Telesis website at www.alliedtelesis.com.
  • Page 5: Table Of Contents

    Contents Preface ....................................11 Document Conventions ...............................12 Contacting Allied Telesis ..............................13 Chapter 1: Overview ................................ 15 AT-DC2552XS / L3 Features...............................16 AT-DC2552XS/L3 Functions ............................16 System Capacity ................................16 AT-DC2552XS/L3 Physical Description ........................19 LEDs ....................................24 SFP+ Slot LED ................................24 QSFP+ Slot LEDs.................................25 Power/Fault LED ................................26 NET MGMT LED ................................27...
  • Page 6 Contents Installing SFP+ Transceiver............................69 Installing an SFP+ Direct Attach Cable ........................71 Installing QSFP+ Transceivers and Cables ........................73 Installing a QSFP+ Transceiver........................... 73 Installing a QSFP+ MTHTP Cable..........................75 Chapter 6: Powering the Switch ............................. 77 Powering On the Switch..............................78 Turning Off the Switch ................................
  • Page 7 Figure 15: Resiliency Link Connecting to Switch Ports Over the Resiliency Link VLAN Using a Network Hub ....41 Figure 16: Stacking Ports ..............................42 Figure 17: Contents of the AT-DC2552XS / L3 Shipping Box ....................52 Figure 18: Contents of the AT-PWR06 Power Supply Module Shipping Box...............53 Figure 19: Contents of the AT-FAN06 Fan Module Shipping Box ..................54...
  • Page 8 Figures...
  • Page 9 Tables Table 1: Twisted Pair Cable Specifications for the NET MGMT Port ..................21 Table 2: SFP+ Slot LED ..............................24 Table 3: QSFP+ LED ................................25 Table 4: Power/Fault LED Description ..........................26 Table 5: NET MGMT LED Descriptions ..........................27 Table 6: FAN Status LED Descriptions ..........................28 Table 7: AC Power LED Description ............................29 Table 8: Installation Procedures ............................46 Table 9: SFP+ Cables .................................68...
  • Page 10 Tables...
  • Page 11: Preface

    Preface This guide contains instructions on how to install the AT-DC2552XS / L3 Enterprise Core Switch and the associated power supply and fan modules on a desktop or in a 19 inch equipment rack. This preface contains the following sections: “Document Conventions”...
  • Page 12: Document Conventions

    Preface Document Conventions This document uses the following conventions: Note Notes provide additional information. Caution Cautions inform you that performing or omitting a specific action may result in equipment damage or loss of data. Warning Warnings inform you that performing or omitting a specific action may result in bodily injury.
  • Page 13: Contacting Allied Telesis

    AT-DC2552XS / L3 Enterprise Core Switch Installation Guide Contacting Allied Telesis If you need assistance with this product, you may contact Allied Telesis technical support by going to the Support & Services section of the Allied Telesis web site at www.alliedtelesis.com/support. You can find links for the following services on this page: 24/7 Online Support —...
  • Page 14 Preface...
  • Page 15: Chapter 1: Overview

    Chapter 1 Overview This chapter contains the following sections: “AT-DC2552XS / L3 Features” on page 16  “LEDs” on page 24  “Console Port” on page 30  “AT-PWR06 Power Supply Module” on page 31  “AT-FAN06 Fan Module” on page 33...
  • Page 16: At-Dc2552Xs / L3 Features

    (1280 Gbps) in a compact 1 RU chassis. The switch’s functions and physical description are described in the following sections: AT-DC2552XS/ A list of the AT-DC2552XS / L3 switch’s functions is as follows: L3 Functions Ports You will find the following network and management ports on the...
  • Page 17  Power Supply/Fan Modules The AT-DC2552XS / L3 must have two fan modules and at least one power supply module installed. You may elect to install a second power supply module for redundancy. The power supply and fan modules are: AT-PWR06 power supply module ...
  • Page 18 Chapter 1: Overview Optional QSFP+ Transceivers The following QSFP+ transceivers direct attach cable assemblies have been approved by Allied Telesis and may be installed in the AT-DC2552XS / L3 chassis: Note The QSFP+ transceivers and direct attach cable assemblies are sold separately from the AT-DC2552XS / L3 Enterprise Core Switch.
  • Page 19: At-Dc2552Xs/L3 Physical Description

    The AT-DC2552XS / L3 Enterprise Core Switch physical description is as follows: L3 Physical Description AT-DC2552XS / L3 Front Panel The front panel of the AT-DC2552XS / L3 is shown in Figure 1. NET MGMT Port LEDs NET MGMT Port (ETH0) Exhaust Air Vents...
  • Page 20 Console Port” on page 82 for more information. Note An RS-232 cable (female USB / D-Sub 9 pin) cable is included with the AT-DC2552XS / L3 shipping container. NET MGMT Port - This 10/100/1000BASE-T RJ-45 Ethernet port  provides the capability to manage the configuration and firmware...
  • Page 21: Table 1: Twisted Pair Cable Specifications For The Net Mgmt Port

    AT-DC2552XS / L3 Enterprise Core Switch Installation Guide command line interface (CLI) or SNMP interface. The port features auto MDI/MDI-X and auto negotiation. The cable requirements of the NET MGMT port are given in Table 1. NET MGMT Port LEDs - These two LEDs display the speed, link ...
  • Page 22: Figure 2: At-Dc2552Xs / L3 Rear Panel View

    Chapter 1: Overview AT-DC2552XS / L3 Rear Panel The rear panel of the AT-DC2552XS / L3 is shown in Figure 2. Blank Covers Fan 1 [Top of Chassis] Fan 2 PS 1 FAN 1 FAN 2 PS 2 Slot Slot...
  • Page 23 AT-DC2552XS / L3 Enterprise Core Switch Installation Guide The fan module slots (FAN 1/FAN 2) are for the installation of the  AT-FAN06 fan module. These slots are located on the center right and center left of the chassis. Two AT-FAN06 fan modules are required in the chassis for normal ...
  • Page 24: Leds

    Chapter 1: Overview LEDs Here are the descriptions of the switch’s LEDs. SFP+ Slot LED Each SFP+ slot has one Link/Activity LED. The LED is triangular in shape. The triangle LED pointing up shows the status of the upper SFP+ slot while the triangle LED pointing down shows the status of the lower SFP+ slot.
  • Page 25: Qsfp+ Slot Leds

    AT-DC2552XS / L3 Enterprise Core Switch Installation Guide QSFP+ Slot LEDs Each QSFP+ port has one link/activity LED labeled LINK/ACT. These LEDs are shown in Figure 4. QSFP+ LEDs Figure 4. QSFP+ LEDs The QSFP+ LED is described in Table 3.
  • Page 26: Power/Fault Led

    Chapter 1: Overview Power/Fault LED The Power/Fault LED is shown in Figure 5. Figure 5. Power/Fault LED The Power/Fault LED is described in Table 4. Table 4. Power/Fault LED Description Location State Description Solid green Power is being supplied and the chassis is operating normally.
  • Page 27: Net Mgmt Led

    AT-DC2552XS / L3 Enterprise Core Switch Installation Guide NET MGMT The NET MGMT LEDs are shown in Figure 6. LINK Figure 6. NET MGMT LEDs The NET MGMT LEDs are described in Table 5. Table 5. NET MGMT LED Descriptions...
  • Page 28: Fan Status Leds

    Chapter 1: Overview FAN Status LEDs The fan status LEDs are shown in Figure 7. Figure 7. FAN Status LEDs The fan status LEDs are described in Table 6. Table 6. FAN Status LED Descriptions Location State Description Solid Green Fan operating normally.
  • Page 29: Ac Power Led

    AT-DC2552XS / L3 Enterprise Core Switch Installation Guide AC Power LED Each AT-PWR06 power supply module has an AC power (AC OK) LED. This LED is shown in Figure 8. Figure 8. AC Power LED The AC Power LED is described in Table 7.
  • Page 30: Console Port

    Chapter 1: Overview Console Port The Console port is a USB connector located on the front panel. See Figure 1 on page 19 for its location. It is used to locally configure the features and parameter settings of the switch. This type of management uses the RS-232 serial communications protocol.
  • Page 31: At-Pwr06 Power Supply Module

    AT-DC2552XS / L3 Enterprise Core Switch Installation Guide AT-PWR06 Power Supply Module The AT-DC2552XS / L3 Enterprise Core Switch is powered by one AT- PWR06 power supply module. A second AT-PWR06 power supply module may be installed for redundancy. The power supply module has an AC connector on the power supply module panel and is installed by the user in slot PS1 or slot PS2.
  • Page 32 Chapter 1: Overview The components of the AT-PWR06 power supply module (see Figure 9 on page 31) are as follows: Power connector - The AC power cable plugs into this connector.  Regional AC power cables are provided in the AT-PWR06 power supply module shipping box.
  • Page 33: At-Fan06 Fan Module

    AT-FAN06 Fan Module Installation of two AT-FAN06 fan modules are required in the AT-DC2552XS / L3. Refer to “Installing and Replacing AT-FAN06 Fan Module” on page 64 for the fan installation procedure. Each AT-FAN06 fan module is equipped with two forced-air cooling fans The fans push air through the chassis from the rear to the front.
  • Page 34 Chapter 1: Overview...
  • Page 35: Chapter 2: Vcstack Overview

    Chapter 2 VCStack Overview The chapter contains the following sections: “VCStack Introduction” on page 36  “Stack Formation” on page 42 ...
  • Page 36: Vcstack Introduction

    For more information, refer to the STACK VIRTUAL-MAC command in the AT-DC2552XS / L3 Management Software Command Line Interface User’s Guide. VCStack Capable VCStack is supported on the following Allied Telesis switch types: Switches SwitchBlade® x8100 Series (VCStack Plus) ...
  • Page 37: The Physical Stack

    Consult the appropriate software reference for stacking functionality of other Allied Telesis switches. The Physical A VCStack can consist of a maximum of two individual AT-DC2552XS / L3 switches, interconnected via high-speed stacking links (QSFP+ ports 49, Stack 53, 57, or 61).
  • Page 38: Resilient Stacked Topology

    49 and 61 on one member are connected to the QSFP+ stacking ports labeled 49 and 61 on the other stack member, respectively. Figure 12. AT-DC2552XS / L3 Stacking Configuration Example Resilient Stacked Where network connectivity uptime is a major criteria, you can use virtual chassis stacking to create highly reliable network configurations.
  • Page 39: Figure 13: Vcstack Resilient Stacked Topology Example

    Note Smaller switches, such as the AT-DC2552XS / L3, can be also be used to form the stacked core or stacked distribution. This network topology supplies multiple dual connections to a number of downstream distribution switches that can in turn connect to user devices.
  • Page 40: Figure 14: Resiliency Link Connecting To Switch Ports Over The Resiliency Link Vlan

    VLAN running over switch-port connections between each stack member. For more information on using the resiliency link commands, refer to the STACK RESILIENCYLINK and SWITCHPORT RESILIENCYLINK commands in the AT-DC2552XS / L3 Management Software Command Line Interface User’s Guide. DC2552XS/L3...
  • Page 41: Figure 15: Resiliency Link Connecting To Switch Ports Over The Resiliency Link Vlan Using A Network Hub

    AT-DC2552XS / L3 Enterprise Core Switch Installation Guide DC2552XS/L3 DC2552XS/L3 Switches Switches Figure 15. Resiliency Link Connecting to Switch Ports Over the Resiliency Link VLAN Using a Network Hub...
  • Page 42: Stack Formation

    Chapter 2: VCStack Overview Stack Formation As previously mentioned, a VCStack always contains a stack (active) master and a stack member (backup). To be part of a stack, a switch must connect to the other potential stack member via dedicated stacking ports. See Figure 16.
  • Page 43 AT-DC2552XS / L3 Enterprise Core Switch Installation Guide The master is the switch with the lowest priority setting, or if the priority settings are equal, the switch with the lowest MAC address will become the stack master. When a stack member is initially booted, its priority value defaults to 128.
  • Page 44 Chapter 2: VCStack Overview...
  • Page 45: Chapter 3: Beginning The Installation

    Chapter 3 Beginning the Installation The chapter contains the following sections: “Installation Overview” on page 46  “Reviewing Safety Precautions” on page 47  “Planning the Installation” on page 51  “Unpacking the Switch” on page 52 ...
  • Page 46: Installation Overview

    Chapter 3: Beginning the Installation Installation Overview Table 8 lists the installation procedures for the AT-DC2552XS / L3 Enterprise Core Switch. The procedures should be performed in the order presented in the table. Table 8. Installation Procedures Step Procedure “Reviewing Safety Precautions” on page 47 “Planning the Installation”...
  • Page 47: Reviewing Safety Precautions

    AT-DC2552XS / L3 Enterprise Core Switch Installation Guide Reviewing Safety Precautions Please review the following safety precautions before you begin to install the switch. Note indicates that a translation of the safety statement is  available in a PDF document titled “Translated Safety Statements”.
  • Page 48 Chapter 3: Beginning the Installation Warning Power cord is used as a disconnection device. To de-energize equipment, disconnect the power cord.  Warning Class I Equipment. This equipment must be earthed. The power plug must be connected to a properly wired earth ground socket outlet.
  • Page 49 AT-DC2552XS / L3 Enterprise Core Switch Installation Guide Note Circuit Overloading: Consideration should be given to the connection of the equipment to the supply circuit and the effect that overloading of circuits might have on overcurrent protection and supply wiring. Appropriate consideration of equipment nameplate ratings should be used when addressing this concern.
  • Page 50 Chapter 3: Beginning the Installation Note If installed in a closed or multi-unit rack assembly, the operating ambient temperature of the rack environment may be greater than the room ambient temperature. Therefore, consideration should be given to installing the equipment in an environment compatible with the manufacturer’s maximum rated ambient temperature (Tmra).
  • Page 51: Planning The Installation

    AT-DC2552XS / L3 Enterprise Core Switch Installation Guide Planning the Installation The AT-DC2552XS / L3 Enterprise Core Switch can be installed on a desktop or in a 19 inch equipment rack. Observe these general requirements when planning the installation of the switch.
  • Page 52: Unpacking The Switch

    If any item in a shipping container is missing or damaged, contact your Allied Telesis sales representative for assistance. AT-DC2552XS/ The contents of the AT-DC2552XS / L3 shipping box are listed in Figure L3 Switch One AT-DC2552XS / L3 switch One 2 m (6.6 ft) local management cable with...
  • Page 53: At-Pwr06 Power Supply

    One regional AC power cord Figure 18. Contents of the AT-PWR06 Power Supply Module Shipping Note The AT-DC2552XS / L3 switch can operate with one power supply module installed. You may elect to install a second power supply module for redundancy.
  • Page 54: At-Fan06 Fan Module

    One AT-FAN06 FAN Module Figure 19. Contents of the AT-FAN06 Fan Module Shipping Box Note The AT-DC2552XS / L3 switch must have two fan modules installed for proper operation. Note The AT-FAN06 fan module is sold and packaged separately from the AT-DC2552XS / L3 Enterprise Core Switch.
  • Page 55: Chapter 4: Installing The Switch And Modules

    Chapter 4 Installing the Switch and Modules You may install the AT-DC2552XS / L3 Switch on a desktop or in a standard 19 inch equipment rack. In addition, you must install at least one AT-PWR06 power supply module and two AT-FAN06 fan modules in the switch chassis.
  • Page 56: Installing The Switch On A Desktop

    Chapter 4: Installing the Switch and Modules Installing the Switch on a Desktop To install the switch on a desktop, perform the following procedure: Note To install the switch in a rack, refer to “Installing the Switch in an Equipment Rack” on page 57. 1.
  • Page 57: Installing The Switch In An Equipment Rack

    To install the switch on a desktop, refer to “Installing the Switch on a Desktop” on page 56. When installing the AT-DC2552XS / L3 switch in a 19 inch rack, it must always be mounted horizontally with the top side up; see Figure 1 on page 19 and Figure 2 on page 22.
  • Page 58: Figure 22: Attaching The Brackets To Switch

    Figure 22. Attaching the Brackets to Switch Caution The chassis may be heavy and awkward to lift. Allied Telesis recommends that you get assistance when mounting the chassis in an equipment rack. ...
  • Page 59: Figure 23: Mounting The Switch In An Equipment Rack

    AT-DC2552XS / L3 Enterprise Core Switch Installation Guide 2. Have another person hold the switch in the equipment rack while you secure it using standard rack mount screws (not provided). Figure 23. Mounting the Switch in an Equipment Rack...
  • Page 60: Installing And Replacing At-Pwr06 Power Supply Module

    There is no functional difference between the two available power supply slots. Operation of the AT-DC2552XS / L3 is the same when installed in either slot. If you want to use only one power supply, Allied Telesis recommends that you install it in the PSU1 slot.
  • Page 61: Figure 25: Insert At-Pwr06 Module Into Chassis

    AT-DC2552XS / L3 Enterprise Core Switch Installation Guide Caution The PSU blank cover should be installed if an AT-PWR06 power sup- ply module is not present in the chassis. This blank cover assures that the correct airflow across the components in the chassis when a power supply module is not installed.
  • Page 62: Replacing Power Supply Module

    Chapter 4: Installing the Switch and Modules 5. Tighten the captive screws to fasten the power supply module to the chassis. See Figure 26. Figure 26. Tighten AT-PWR06 Captive Screws 6. The next step in the installation process is installing the fan modules. Go to “Installing Fan Module”...
  • Page 63: Installing Power Supply Blank Cover

    AT-DC2552XS / L3 Enterprise Core Switch Installation Guide Note If a new AT-PWR06 power supply module is not available to replace the module you are removing, perform the procedure outlined in “Installing Power Supply Blank Cover” on page 63. 4. Slowly insert the new AT-PWR06 power supply module into the PSU slot until it is flush with the rear of the chassis.
  • Page 64: Installing And Replacing At-Fan06 Fan Module

    Chapter 4: Installing the Switch and Modules Installing and Replacing AT-FAN06 Fan Module The following procedures are included in this section: “Installing Fan Module”  “Replacing Fan Module” on page 66  The AT-FAN06 fan module is hot swappable within the chassis. Installing Fan Perform the following procedure to install an AT-FAN06 fan module: Module...
  • Page 65: Figure 29: Tighten At-Fan06 Captive Screws

    Warning To operate this product, two fan modules must be installed. Operation of the AT-DC2552XS / L3 Enterprise Core Switch with one fan module will cause the chassis to overheat. 6. The next step in the installation process is installing the SFP+ transceivers.
  • Page 66: Replacing Fan Module

    Warning The chassis cooling is designed to operate with two fan modules operating together. To avoid overheating of the AT-DC2552XS / L3 chassis, please complete the following procedure within one minute. 1. Loosen the captive screws on the AT-FAN06 fan module.
  • Page 67: Chapter 5: Installing The Sfp+ And Qsfp+ Transceivers And Cables

    Transceivers and Cables The list of approved SFP+ and QSFP+ transceivers and direct connect cables that may be installed in the AT-DC2552XS / L3 chassis are given in “Optional SFP+ Transceivers” on page 17 and “Optional QSFP+ Transceivers” on page 18.
  • Page 68: Installing Sfp+ Transceivers And Cables

    Go to “Optional SFP+ Transceivers” on page 17 for a list of  approved SFP+ transceivers for the AT-DC2552XS / L3. Allied Telesis recommends using the following SFP+ cables listed ...
  • Page 69: Installing Sfp+ Transceiver

    AT-DC2552XS / L3 Enterprise Core Switch Installation Guide Installing SFP+ Perform the following procedure to install an SFP+ transceiver: Transceiver 1. Remove the dust plug from an SFP+ slot on the switch. See Figure 30. Figure 30. Removing the Dust Plug from an SFP+ Slot 2.
  • Page 70: Figure 32: Installing An Sfp+ Transceiver

    Chapter 5: Installing the SFP+ and QSFP+ Transceivers and Cables 5. Slide the module into the slot until it snaps into place as shown in Figure 32. Figure 32. Installing an SFP+ Transceiver Note If you are ready to attach the fiber optic cable to the transceiver, continue with the next step.
  • Page 71: Installing An Sfp+ Direct Attach Cable

    3. If you are installing the direct attach cable in a top SFP+ slot, position it with the Allied Telesis label and tab facing up. If you are installing the direct attach cable in a bottom slot, position the it so that the label and...
  • Page 72: Figure 36: Installing An Sfp+ Direct Attach Cable

    Chapter 5: Installing the SFP+ and QSFP+ Transceivers and Cables 4. Slide the direct attach cable into the slot until it snaps in place. See Figure 36. Figure 36. Installing an SFP+ Direct Attach Cable 5. Repeat Step 1 through Step 4 of this procedure if you have other SFP+ direct attach cables to install.
  • Page 73: Installing Qsfp+ Transceivers And Cables

    AT-DC2552XS / L3 Enterprise Core Switch Installation Guide Installing QSFP+ Transceivers and Cables Review the following guidelines before installing optional QSFP+ transceivers in the switch: QSFP+ transceivers can be hot-swapped while the switch is  powered on. However, you should always disconnect the fiber optic cables first before removing a module.
  • Page 74: Figure 37: Removing Qsfp+ Slot Dust Cover

    Figure 37. Removing QSFP+ Slot Dust Cover 3. If you are installing the transceiver in the top QSFP+ slot, position the transceiver with the Allied Telesis handle facing up. If you are installing the transceiver in the bottom slot, position the transceiver with the handle facing down.
  • Page 75: Installing A Qsfp+ Mthtp Cable

    AT-DC2552XS / L3 Enterprise Core Switch Installation Guide Figure 39. Removing QSFP+ Dust Cover 7. Insert the fiber optic cable to the port on the transceiver, as shown in Figure 40, until it clicks in place. Figure 40. Attaching a Fiber Optic Cable to a QSFP+ Transceiver 8.
  • Page 76: Figure 41: Removing Qsfp+ Slot Dust Cover

    Chapter 5: Installing the SFP+ and QSFP+ Transceivers and Cables Figure 41. Removing QSFP+ Slot Dust Cover 3. If you are installing the QSFP+ MTHTP cable in the top QSFP+ slot, position the cable with the tab facing up. If you are installing the module in the bottom slot, position the cable with the tab facing down.
  • Page 77: Chapter 6: Powering The Switch

    Chapter 6 Powering the Switch The procedures in this chapter are listed here: “Powering On the Switch” on page 78  “Turning Off the Switch” on page 80 ...
  • Page 78: Powering On The Switch

    Refer to “Installing and Replacing AT-PWR06 Power Supply Module” on page 60. 1. Inspect the rear of the AT-DC2552XS / L3 chassis to insure that at least one AT-PWR06 power supply module and two AT-FAN06 fan modules are installed. If one of these modules needs to be installed, perform the steps described in “Installing Power Supply Module”...
  • Page 79 Step 1 - Step 3. 6. The next step in the installation process is to access the AT-DC2552XS / L3 management interface. Go to Chapter 7, “Connecting the Console Port” on page 82 for instructions on...
  • Page 80: Turning Off The Switch

    Chapter 6: Powering the Switch Turning Off the Switch To turn off the AC power to the switch, disconnect the power plug from the power outlet. If you have two AT-PWR06 power supply modules installed, be sure to disconnect the AC power plugs to both power supply modules. Warning Power cord is used as a disconnection device.
  • Page 81: Chapter 7: Managing The Switch

    Chapter 7 Managing the Switch You may manage an AT-DC2552XS / L3 Enterprise Core Switch with these methods and tools: Local management via Telnet client  Remote management via Telnet client  Remote management via SNMPv1, v2C, v3  This chapter contains the following procedures to manage the switch: “Local Management”...
  • Page 82: Local Management

    Chapter 7: Managing the Switch Local Management You can manage the AT-DC2552XS / L3 switch locally through the Console port (USB connector) on the front panel of the switch. This is called local management or out-of-band management because the management sessions are not connected over your Ethernet network. The...
  • Page 83 AT-DC2552XS / L3 Enterprise Core Switch Installation Guide Stop bits: 1  Flow control: None  Note The port settings are for a DEC VT100 or ANSI terminal, or an equivalent terminal emulator program. 4. Press Enter. You are prompted for a user name and password.
  • Page 84: Remote Network Management

    Chapter 7: Managing the Switch Remote Network Management You can manage the AT-DC2552XS / L3 switch remotely through any of the Ethernet ports (1 through 64) or through or the NET MGMT (ETH0) Ethernet port on the front panel of the switch. See Figure 1 on page 19 for the location of these ports.
  • Page 85: Figure 44: Connecting The Twisted Pair Cable Into The Net Mgmt Port

    AT-DC2552XS / L3 Enterprise Core Switch Installation Guide Figure 44. Connecting the Twisted Pair Cable into the NET MGMT port 3. With the AT-DC2552XS / L3 and link partner network device powered on, verify that the NET MGMT port LINK/ACT LED is either amber or green.
  • Page 86 Chapter 7: Managing the Switch...
  • Page 87: Chapter 8: Troubleshooting

    Note For further assistance, please contact Allied Telesis Technical Support. Refer to “Contacting Allied Telesis” on page 13. Problem: The NET MGMT twisted pair port on the switch is connected to a network device but the port’s LINK/ACT LED is off.
  • Page 88 Use the switch’s management software to verify that the port is  enabled. Refer to AT-DC2552XS / L3 Management Software Command Line Interface User’s Guide for information concerning specific commands.
  • Page 89 AT-DC2552XS / L3 Enterprise Core Switch Installation Guide Test the attenuation on the fiber optic cable with a fiber optic tester  to determine whether the input optical signal is too weak (sensitivity) or too strong (maximum input power).
  • Page 90 Chapter 8: Troubleshooting...
  • Page 91: Appendix A: Technical Specifications

     Physical Specifications Dimensions (H x W x D) Table 11. Product Dimensions Model Specification AT-DC2552XS / L3 44.0 x 46.0 x 4.4 cm (17.3 x 18.1 x 1.7 inch) Weights Table 12. Product Weights Model Specifications AT-DC2552XS / L3 7.2 kg (15.9 lb.)
  • Page 92: Environmental Specifications

    Appendix A: Technical Specifications Environmental Specifications Table 13. Environmental Specifications Model Specifications Operating Temperature 0° C to 40° C (32° F to 104° F) Storage Temperature -20° C to 60° C (-4° F to 140° F) Operating Humidity 0% to 80% noncondensing Storage Humidity 0% to 90% noncondensing Power Specifications...
  • Page 93: Console Port Pinouts

    AT-DC2552XS / L3 Enterprise Core Switch Installation Guide Console Port Pinouts Figure 45 illustrates the pin locations of the USB Console connector. Figure 45. USB Console Connector and Port Pin Layout Table 16 lists the pinout functions for the Console port connector.
  • Page 94: Twisted Pair Port Pinouts

    Appendix A: Technical Specifications RJ-45 Twisted Pair Port Pinouts Figure 46 illustrates the pin layout of an RJ-45 connector and port. Figure 46. RJ-45 Connector and Port Pin Layout Table 17 lists the pin signals for 10 and 100 Mbps. Table 17.
  • Page 95: Table 18: Pin Signals - 1000 Mbps

    AT-DC2552XS / L3 Enterprise Core Switch Installation Guide Table 18 lists the pin signals when a port operating at 1000 Mbps. Table 18. Pin Signals - 1000 Mbps Pinout Pair Pair 1 + Pair 1 - Pair 2 + Pair 3 +...
  • Page 96 Appendix A: Technical Specifications...

This manual is also suitable for:

At-dc2552xsl3

Table of Contents