Connecting A Cell Station To The Pbx - Panasonic KX-TAW848 Installation Manual

Advanced hybrid & wireless pbx
Hide thumbs Also See for KX-TAW848:
Table of Contents

Advertisement

2.7.7

Connecting a Cell Station to the PBX

Refer to the following example to connect a CS to the PBX.
A Hybrid Port or HLC4 card (RJ11)
Signal Name
Pin No.
D1
D2
Accessory and User-supplied Items for the CS
Accessory (included): Screws × 2, Washers × 2
User-supplied (not included): RJ11 connector
Note
For details about HLC4 card, refer to "2.4.1 HLC4 Card".
Hybrid Port
Cable
26 AWG:
24 AWG:
22 AWG:
CAT 5:
1
2
3
4
2.7 Connection of 2.4 GHz Portable Stations
Maximum Distance
Under 222 m (728 ft)
Under 347 m (1138 ft)
Under 500 m (1640 ft)
Under 347 m (1138 ft)
CS (RJ11)
Pin No.
Signal Name
1
2
3
4
D1
D2
Installation Manual