Fireplace Installation
Figure 3
Hardwire
Bracket
cord bracket from the back of the
fireplace by removing the three
retaining screws. (Figure 3)
2. Remove the two wire access
covers off of the unit at the front
to access the wire connections.
(Figure 4)
3. Pull the wires and connectors out
of the back opening.
4. Unscrew the three wire connec-
tors inside the electrical box and
separate the wires.
5. Install the supplied hardwire
bracket (with the ½" wire hole)
onto the firebox. (Figure 3)
6. Leaving a minimum of 3 in. (7.6
cm) of slack, route the power
supply wires through the hole in
the electrical cover bracket and
secure with a wire clamp (not
supplied).
7. Connect the black wire (L) from
Electrical
Cord Bracket
Screws
8. Connect the blue and white wires
9. Connect the green wire (G) from
10. Reposition the wire access covers
11. Refer to Front Glass Installa-
Figure 4
Wire Access
Covers
the unit to the live wire from the
power supply using one of the
wire connectors removed in step
4.
(N) from the unit to the neutral
wire from the power supply using
the second wire connector from
step 4.
the unit to the ground wire from
the power supply using the third
wire connector from step 4.
over the wires and connectors
and attach to fireplace chassis us-
ing the screws removed in step 2.
tion section for final installation
procedures.
9