Partial Recessed Installation - 2X4 Framing - Dimplex BLF3451 Owner's Manual

Electric fireplace
Hide thumbs Also See for BLF3451:
Table of Contents

Advertisement

Fireplace Installation
with the bubble level on the top,
on the wall so that the bubble on
the level is centered between the
two black lines.
4. Mark the 3 mounting screw
locations, on the wall, ensuring
that the wall bracket stays level.
(Figure 5)
5. In locations where the screws are
being installed only into drywall,
install the supplied wall anchors
before installing the screw (predrill
if required).
6. Secure the wall bracket to the wall
using the supplied 1½ in. (3.8 cm)
mounting screws and washers
into the wall and/or wall anchors.
7. Install the bottom support bracket
to the wall centered with the
wall mounting bracket, using the
appropriate mounting hardware,
13 ¾" (350 mm) below the wall
mounting bracket. (Figure 5)
8. Remove the center back screw
Figure 7
2 x 4 Framing
from the bottom of the fireplace.
(Figure 6)
9. Hang the fireplace from the
bracket.
10. Install the removed screw through
the bottom support bracket into
the fireplace.
11. Refer to Front Glass Installa-
tion section for final installation
procedures.
Partial Recessed
Installation - 2x4 Framing
CAUTION: Two people may be
required for various steps of this
procedure.
1. Prepare a wall with a framed
opening of 30 ½ in. (77.5 cm)
wide x 16 ½ in. (42 cm) high
(Figure 7).
!
NOTE: The sizing has allowed for
¼ in. (6.4 mm) around the fireplace
insert for ease of installation. This
fireplace does not require any ad-
ditional venting.
!
NOTE: It is recommended that
the bottom of the unit not be mounted
higher than 40 in. (102 cm) from the
ground to maintain an optimized view-
ing angle of the flame.
2. Choose your method of supplying
power to the unit:
• Plug in (you may run the power
cord out of the framed wall open-
ing to an existing outlet or install
11