Removing The Intel Raid Smart Battery; Removing And Installing The Fixed Power Supply; Removing The Fixed Power Supply; Figure 62. Installing The Intel Raid Smart Battery - Intel S2600CP Service Manual

Server board/system family
Hide thumbs Also See for S2600CP:
Table of Contents

Advertisement

Hardware Installations and Upgrades
Removing the Intel
1. Pull the tab until the tab is disengaged from the chassis cut.
2. Slide the battery from the server chassis side wall and move it out of the opening in the fan
bulkhead.
3. Lift the battery up to remove it from the server chassis.

Removing and Installing the Fixed Power Supply

WARNING
Hazardous voltage, current, and energy levels are present inside the power supply.
There are no user-serviceable parts inside it; servicing should be done by technically
qualified personnel.

Removing the Fixed Power Supply

1. Observe the safety and ESD precautions at the beginning of this book.
2. Power down the server and unplug all peripheral devices and the AC power cable.
3. Remove the chassis cover. For instructions, see "Removing the Chassis Cover".
4. Remove the airduct if it is installed. For instructions, see "Installing the Airduct".
5. Disconnect all internal power cables from chassis components and server board.
6. Rotate the power supply locking device counter-clockwise (see letter "A") and remove the
fixed power supply (see letter "B").
40
Intel
Figure 62. Installing the Intel
®
RAID Smart Battery
Figure 63. Removing the Intel
®
Server Board S2600CP Family Intel
®
RAID Smart Battery
®
RAID Smart Battery
®
Server System P4000CP Family Service Guide