GS ( k
Setup and print symbol
Function 065: Sets the number of columns of the data area for PDF417.
Function 066: Sets the number of rows of data area for PDF417.
Function 067: Sets the module width of one PDF417 symbol to n dots.
Function 068: Sets the module height.
Function 069: Sets the error correction level for PDF417 symbols.
Function 070: Specifies or cancels various PDF417 symbol options.
Function 080: Stores symbol data in the PDF417 symbol storage area.
Function 081: Prints the PDF417 symbol data in the symbol storage area.
Function 082: Transmits the size of the symbol data in the symbol storage area.
Function 165: Specifies the mode for QRCode symbol.
Function 167: Sets the size of the QRCode symbol module.
Function 169: Sets the error correction level for QRCode symbol.
Function 180: Stores symbol data in the QRCode symbol storage area.
Function 181: Prints the QRCode symbol data in the symbol storage area.
Function 182: Transmits the size of the symbol data in the symbol storage area.
Function 265: Specifies the mode for MaxiCode symbol.
Function 280: Stores symbol data in the MaxiCode symbol storage area.
Function 281: Prints the MaxiCode symbol data in the symbol storage area.
Function 282: Transmits the size of the encoded symbol data in the symbol storage area.
GS *
Define downloaded bit image
GS /
Print downloaded bit image
GS :
Start/end macro definition
GS B
Turn white/black reverse printing mode on/off
GS C 0
Select counter print mode
GS C 1
Select count mode (A) (in label mode)
GS C 2
Set counter (in label mode)
GS C ;
Select count mode (B) (in label mode)
GS H
Select printing position of HRI characters
GS I
Transmit printer ID
GS L
Set left margin
GS P
Set horizontal and vertical motion units
GS T
Set print position to the beginning of print line
GS V
Select cut mode and cut paper
GS W
Set printing area width
GS \
Set relative vertical print position in page mode
GS ^
Execute macro
GS a
Enable/disable Automatic Status Back (ASB)
GS b
Turn smoothing mode on/off
GS c
Print counter
GS f
Select font for HRI characters
GS g 0
Initialize maintenance counter
GS g 2
Transmit maintenance counter
GS h
Set bar code height
GS k
Print bar code
GS r
Transmit status
GS v 0
Print raster bit image
GS w
Set bar code width