68
Hardware Maintenance Manual
Diagnostic Error Code
035-197-XXX
RAID interface test warning
035-198-XXX
RAID interface test aborted
035-199-XXX
RAID interface test failed, cause unknown
071-000-XXX
Audio port Interface Test Passed
071-00X-XXX
071-01X-XXX
071-02X-XXX
Audio port error
071-03X-XXX
Audio port failure
071-04X-XXX
Audio port failure
071-195-XXX
Audio port Test aborted by user
071-196-XXX
Audio port test halt, error threshold
exceeded
071-197-XXX
Audio port test warning
FRU/Action
1. Make sure the component that is called
out is connected and/or enabled. See .
2. Re-run the test.
3. Replace the component that is called out
in warning statement.
4. Replace the component under test.
1. If a component is called out, make sure it
is connected and/or enabled. See .
2. Flash the system and re-test. See
"Updating (flashing) BIOS from a disc"
on page 326.
3. Go to "Undetermined problems" on page
78.
1. See "Undetermined problems" on page
78.
2. Flash the system and re-test. See
"Updating (flashing) BIOS from a disc"
on page 326.
3. Replace component under function test.
No action
1. Run the Setup Utility program.
2. Flash the system. See "Updating
(flashing) BIOS from a disc" on page 326.
3. System board
1. Speakers
2. Microphone
3. Audio card, if installed
4. System board
1. Run the Setup Utility program.
2. Audio card, if installed
3. System board
Information only
Restart the test, if necessary.
1. Press F3 to review the log file.
2. Restart the test to reset the log file.
1. Make sure the component that is called
out is connected and/or enabled. See .
2. Re-run the test.
3. Replace the component that is called out
in warning statement.
4. Replace the component under test.