Advertisement

Diagnostic Error Code
030-027-XXX
SCSI interface Configuration/Setup error
030-03X-XXX
030-04X-XXX
SCSI interface error
030-195-XXX
SCSI interface Test aborted by user
030-196-XXX
SCSI interface test halt, error threshold
exceeded
030-197-XXX
SCSI interface test warning
030-198-XXX
SCSI interface test aborted
030-199-XXX
SCSI interface test failed, cause unknown
035-000-XXX
RAID interface Test Passed
035-0XX-XXX
RAID interface Failure
035-195-XXX
RAID interface Test aborted by user
035-196-XXX
RAID interface test halt, error threshold
exceeded
FRU/Action
1. SCSI signal cable
2. Flash the system. See "Updating
(flashing) BIOS from a disc" on page 326
3. SCSI device
4. SCSI adapter card, if installed
5. System board
1. SCSI signal cable
2. Check AC/DC power adapter
3. SCSI device
4. SCSI adapter card, if installed
5. System board
Information only
Restart the test, if necessary.
1. Press F3 to review the log file.
2. Restart the test to reset the log file.
1. Make sure the component that is called
out is connected and/or enabled. See .
2. Re-run the test.
3. Replace the component that is called out
in warning statement.
4. Replace the component under test.
1. If a component is called out, make sure it
is connected and/or enabled. See .
2. Flash the system and re-test. See
"Updating (flashing) BIOS from a disc"
on page 326.
3. Go to "Undetermined problems" on page
78.
1. Go to "Undetermined problems" on page
78.
2. Flash the system and re-test. See
"Updating (flashing) BIOS from a disc"
on page 326.
3. Replace component under function test.
No action
1. RAID signal cable
2. RAID device
3. RAID adapter card, if installed
4. System board
Information only
Restart the test, if necessary.
1. Press F3 to review the log file.