RECEIPT:
It is essential to inspect the unit immediately when it arrives. NUVU® has placed instructions on
the packaging to help avoid damage in transit. However, accidents or negligent handling can
produce hidden damage. These steps should be followed:
A. Inspect the entire perimeter of the package for damage or punctures to the packing
material. This may indicate damage to the unit inside. Call any and all packing damage
to the attention of the delivery person.
B.
If any packing damage is found uncrate the unit immediately in the presence of the
delivery person to determine if the unit is damaged. If any damage is found indicate the
type and amount of damage on the shipping documents and notify NUVU® at (906) 863-
4401 immediately after filing a freight claim.
C. Uncrate the unit carefully and check the entire unit (top, sides, front and back) for any
visible or hidden damage.
D. Remove the unit from the shipping pallet and inspect the bottom for any damage.
E.
If any damage is noted after the driver leaves immediately contact the freight company
and NUVU® Food Service Systems.
F.
Check the Door(s). Make sure each Door closes completely, and that the Door Gasket
seals firmly (refer to the DOOR TEST PROCEDURE under DOOR LATCH, How to
Adjust in the SERVICE AND REPLACEMENT GUIDE). If it does not close and seal
properly please contact the TOASTMASTER® Service Department for instructions and
assistance in any required adjustments.

INSTALLATION PROCEDURES:

NUVU® recommends that your RM/RA series model be installed by a licensed professional to
ensure proper positioning and connections. Failure to install your RM/RA series model properly
may void your product warranty.
Position the unit where it will be operated, allowing adequate clearances around the unit for proper
cooling and operation. NUVU® recommends a minimum clearance of 4" at the back and on each
side of the Oven. Make sure the unit sits level and solid. Adjust or shim the Casters or Oven base
as necessary.
Check to determine that the power source is the same voltage and phase as that indicated on the
label on the side of the unit. If the voltage and/or phase is not the same call NUVU® service
department.
IMPORTANT: DO NOT ATTACH UNIT IF THE POWER SOURCE DOES NOT
COINCIDE WITH THE UNIT LABEL!!!
NUVU®
page 8
SALES FAX (906) 863-5889 • SERVICE FAX (906) 863-6322
RM/RA SERIES OWNER'S MANUAL
MENOMINEE, MICHIGAN 49858
(906) 863-4401

Advertisement

Table of Contents
loading

This manual is also suitable for:

Rm-5tRa-5tRa-4t

Table of Contents