Table 3. Firmware Error Codes. (continued)
Error Code Description
40110000 Loss of a redundant power supply was
40110001 Power supply failed
40110002 Missing voltage on both processor cards
40110003 Missing voltage on one processor card
142
Service Guide
detected
Action / Possible Failing FRU
1. If a location code is displayed with
this error code, replace the part at
that location.
2. Look at the service processor error
log for more error information.
3. Reseat the power supplies
4. Replace the power supplies
one-at-a-time.
Location: P3-V1
Location: P3-V2
Location: P3-V3
1. If a location code is displayed with
this error code, replace the part at
that location.
2. Look at the service processor error
log for more error information.
3. Reseat the power supplies
4. Replace the power supplies
one-at-a-time.
Location: P3-V1
Location: P3-V2
Location: P3-V3
5. Replace the system board
Location: P1
(See note 3 on page 115.)
1. If a location code is displayed with
this error code, replace the part at
that location.
2. Look at the service processor error
log for more error information.
3. Reseat the power supplies
4. Replace the power supplies
one-at-a-time.
Location: P3-V1
Location: P3-V2
Location: P3-V3
If AIX is running, check the AIX error
log to find out which processor card is
failing. If AIX in not available, check
the service processor error log.
Replace the failing processor.
Location: P1-C1 or P1-C2.