Table 2. Firmware Checkpoints. (continued)
Checkpoint
E1F7
E1FB
E1FD
E201
E202
E203
E204
E206
E207
E208
E209
E20A
106
Service Guide
Description
No boot image located.
Scan SCSI bus for attached devices.
Default Catch
Setup PHB BARC addresses.
Initialize PHB registers and PHB's PCI
configuration registers.
Look for PCI to ISA bridge.
Setup ISA bridge, PCI config. registers,
and initialize
Check for 50 MHz device on PCI bus in
slot 1P or 2P.
Setup data gather mode and 64/32-bit
mode on PCG.
Assign bus number on PCG.
Assign PCI I/O addresses on PCI.
Assign PCI I/O addresses on PCG.
Action/ Possible Failing FRU
Use the System Management Services
menus to modify the boot sequence
(also known as boot list ) to include
devices that are known to contain a
copy of the operating system. For
example, select a hard disk known to
have a copy of the operating system as
the first and only device in the boot
sequence (boot list) and attempt to boot
again.
See "Unresolved Checkpoint Problems"
on page 85.
The operator panel will alternate
between the code E1FD and another
Exxx code, where Exxx is the point at
which the error occurred. If the Exxx is
not listed in this table, go to "MAP 1540:
Minimum Configuration" on page 63.
Go to MAP 1540: Minimum
Configuration, "Step 1540-24" on
page 81.
Go to MAP 1540: Minimum
Configuration, "Step 1540-24" on
page 81.
Go to MAP 1540: Minimum
Configuration, "Step 1540-24" on
page 81.
Go to MAP 1540: Minimum
Configuration, "Step 1540-24" on
page 81.
Go to MAP 1540: Minimum
Configuration, "Step 1540-24" on
page 81.
Go to MAP 1540: Minimum
Configuration, "Step 1540-24" on
page 81.
Go to MAP 1540: Minimum
Configuration, "Step 1540-24" on
page 81.
Go to MAP 1540: Minimum
Configuration, "Step 1540-24" on
page 81.
Go to MAP 1540: Minimum
Configuration, "Step 1540-24" on
page 81.

Advertisement