Page 4
This product is UL listed to US and Canadien safety standards Ce produit est homologué UL (conforme aux normes de sécurité américaines et candiennes) Producto homologado según normas de seguridad americanas y canadienses Produto homologado de accordo com as normas de segurança americanas e canadianas Printed: 07.07.2013 | Doc-Nr: PUB / 5069460 / 000 / 00...
ORIGINAL OPERATING INSTRUCTIONS DAG 450 S/ DAG 450 D angle grinder 1These numbers refer to the corresponding illustra- It is essential that the operating instruc- tions. The illustrations can be found on the fold-out tions are read before the power tool is op- cover pages.
Wear housing. Make a note of this data in your operating protection. protection protective instructions and always refer to it when making an gloves enquiry to your Hilti representative or service depart- ment. Type: Wear Generation: 02 breathing protection Serial no.:...
Page 7
The power tool may be used only for dry cutting or grinding. Cutting or grinding materials containing asbestos is not permissible. To avoid the risk of injury, use only genuine Hilti accessories and insert tools. Observe the information printed in the operating instructions concerning operation, care and maintenance.
Dimensions (L x H x W) without DAG 450 D hood 271 mm x 103 mm x 75 mm 2.0 kg Weight of tool, DAG 450-S Weight of tool, DAG 450-D 2.1 kg Information about the power tool and applications Drive spindle thread (arbor size) "...
5. Safety instructions A moment of inattention while operating power 5.1 General safety warnings tools may result in serious personal injury. WARNING! Read all instructions! Failure to follow all b) Use safety equipment. Always wear eye pro- instructions listed below may result in electric shock, tection.
Page 10
the power tool. Power tools are dangerous in the e) The outside diameter and the thickness of your hands of untrained users. accessory must be within the capacity rating of your power tool. Incorrectly sized accessories e) Maintain power tools. Check for misalignment or binding of moving parts, breakage of parts cannot be adequately guarded or controlled.
Page 11
l) Never lay the power tool down until the access- c) Do not position your body in the area where ory has come to a complete stop. The spinning power tool will move if kickback occurs. Kick- accessory may grab the surface and pull the back will propel the tool in direction opposite to power tool out of your control.
Page 12
or brush may expand in diameter due to work ing or binding of the wheel in the cut and the load and centrifugal forces. possibility of kickback or wheel breakage. b) Do not position your body in line with and behind 5.2.7 Personal safety the rotating wheel.
Page 13
Hilti Service Center. interrupter (GFCI) with a rating of max. 30 mA h) Take steps to ensure that flying sparks from (tripping current).
6. Before use DANGER Check the condition of the grinding disc before using it. Do not use discs that are broken, cracked or damaged in any way. WARNING Disconnect the supply cord plug from the power Never use the power tool without the guard. outlet.
7. Operation CAUTION The insert tool may get hot during use. Wear protect- ive gloves when changing insert tools. WARNING Reduce the load on the power tool by avoiding Wear ear protectors. Exposure to noise can cause tilting the disc in the kerf when cutting. The disc hearing loss.
Under such conditions, necessary, the power tool should be repaired by the tool should be plugged into a ground fault Hilti Service. circuit interrupter (GFCI) and use of a stationary WARNING dust removal system and frequent cleaning of the Repairs to the electrical section of the power tool tool’s cooling air slots is recommended.
10. Disposal Most of the materials from which Hilti power tools or appliances are manufactured can be recycled. The materials must be correctly separated before they can be recycled. In many countries, Hilti has already made arrangements for taking back your old power tools or appliances for recycling.