Test Equipment - Ecobee Smart Si Installation Manual

Hide thumbs Also See for Smart Si:
Table of Contents

Advertisement

To test the equipment:
From the Home screen,
press MENU.
Settings
Select
Installation
Settings.
Test
Equipment.
Select
Select OK.
Test the equipment
connected to the
thermostat by turning each
component on and off.
30
Heat Min On Time
equipment run time in heat mode: 1 to 20 min
(default is 5 min).
Temp Correction
Lets you program an offset between the real
temperature at thermostat and the displayed
temperature. If you find that the temperature
where the thermostat is located does not
represent the room temperature, change the
offset to compensate for the difference. The
correct temperature is adjustable from +/- 10°F
in 0.5°F (0.3°C) increments.
Installer Code
To prevent accidental modifications to the
installation settings, you can enable a 4-digit
installer code. This code is pre-programmed to
3262.

Test Equipment

These options let you test the wiring and
connections of the devices connected to the
thermostat by turning them on or off.
The equipment will turn off when you exit the
menu.
Warning: Compressor protection and
!
minimum run-time features are not
enforced while in this mode.
Sets the minimum