28
and set temperature before the system calls
for heat. A smaller difference means shorter
cycle times, whereas a larger difference results
in longer cycle times. The temperature range
is adjustable from 0 to 3 °F (-17.5 to 26.5 °C) in
0.5°F (0.3°C) increments.
Heat Dissipation Time
the fan will run after the heat set point has
been reached and the call for heat has been
turned off. Running the fan for a period of
time allows for any heated air left in the ducts
to circulate throughout the home. The time is
adjustable from 0 to 900 seconds. The default
value is 30 seconds.
Cool Differential Temp
difference between the current temperature
and set temperature before the system calls
for cool. A smaller difference means shorter
cycle times, whereas a larger difference results
in longer cycle times. The temperature range
is adjustable from 0 to 3 °F (0.3 to 1.7 °C) in
0.5°F (0.3°C) increments.
Cool Dissipation Time
the fan will run after the cool has been turned
off. Running the fan for a period of time allows
for any cooled air left in the ducts to circulate
throughout the home. The time is adjustable
from 0 to 900 seconds. The default value is 30
seconds.
Advanced Settings
These options customize how long each stage
will run before the next stage turns on. You may
also program when a particular stage is turned
on based on the temperature delta between the
set temperature and the current temperature.
The amount of time
The minimum
The amount of time