  • Page 1: Installation Manual

    ©2009 ecobee 333 Adelaide Street West / 6th Floor Toronto / Ontario / M5V 1R5 / Canada toll free 1.877.932.6233 www.ecobee.com SMART THERMOSTAT MA-106-0003-R3 Installation Manual Printed in Canada...
  • Page 2: Table Of Contents

    HVAC System Compatability Information environment. Specifications The ecobee Smart Thermostat has been designed Installing the ecobee Smart Thermostat in partnership with HVAC contractors to ensure Wiring Diagrams that the installation process is simple and efficient.
  • Page 3: Hvac System Compatibility Information

    Before you begin ecobee supports control of up to four heating stages and two cooling stages. It also supports control of humidifiers, dehumidifiers, This product is intended to be installed by trained, service profes- heat recovery ventilators and energy recovery ventilators.
  • Page 4: Specifications

    Dry contact only Dry contact only Dimensions IN1- Input 1 - Dry contact only Dry contact only Smart Thermostat: 5.5”W x 3.25”H x 1”D (139.5mm H x 82.5mm W x IN2+ Input 2 + Dry contact only Dry contact only 25mm D) Equipment Interface: 4.6”W x 10”H x 1.3”D (118mm W x 254mm H x...
  • Page 5: Installing The Ecobee Smart Thermostat

    INSTAllING THE SMART THERMOSTAT There are five steps to installing the ecobee Smart Thermostat: Step 1: Install the Equipment Interface. Step 2: Wire the Equipment Interface. Step 3: Install the Smart Thermostat. Step 4: Connect the Smart Thermostat to the Equipment Interface.
  • Page 6: Wiring Diagrams

    Wiring diagrams Below is the Equipment Interface Terminal Labels 24 Vac Comp 1 Power W O/B Changeover System W2 AUX Aux (3rd Heat) Line W O/B Communications W2 AUX ACC1 ACC1r Aux 2 (4th Heat) ACC2 ACC1 IN2- ACC2r Comp 2 ACC1r IN2+ ACC3...
  • Page 7: Installing The Smart Thermostat

    Max Input ACCr Insert screwdriver into one of two slots and twist gently Place the Smart Thermostat backplate on the wall. Make sure that any existing wires can be inserted through the opening for the wiring. Line In Using the backplate as a template, mark the location of the mount- Ventilator Heat Recovery ing holes on the wall as shown below.
  • Page 8: Connecting Power

    Replace the front cover ensuring the pins meet the terminals the Equipment Interface Connecting power Only four wires are required to connect the Smart Thermostat to the Equipment Interface. If you are replacing a thermostat, you can use Once you’ve completed the wiring of the Smart Thermostat and the existing wiring.
  • Page 9: Equipment Interface Status Led

    Once the Smart Thermostat and Equipment Interface are powered up LED arrangement and working correctly, you can begin configuring the system. The Smart Thermostat uses touch screen technology, so it’s easy to The LEDs operate as follows: navigate – just tap the icons, buttons and lists.
  • Page 10: Configuring The Installer Settings

    In addition to the Installation Wizard, the equipment setting will Ventilator allow you to manually configure the various devices that are Note: The Smart Thermostat will automatically turn on the system fan connected to the Equipment Interface. whenever it turns on the ventilator relay.
  • Page 11: Contractor Info

    Website address Installer Code If you are a register ecobee contractor, you will have access to the This option lets you enable or disable 3262 as the installer code. Contractor portal. On this portal you can enter the serial number of...
  • Page 12: Configuring The Reminder Alerts

    Use the scroll bar at the right of the list to Temperature Alerts From the Home see all the settings. The Smart Thermostat can generate alerts when the temperature in Screen, press More. the home reaches a pre-programmed level. This protects the home Maintenance from damage due to freezing and/or excessive heat.
  • Page 13: Performing Ahardware Reset

    In a heat pump, with auxiliary heat configuration, you can program the HARDWARE RESET Smart Thermostat to generate an alert if the auxiliary heat runs for more than this programmed amount of time during a 24 hour period. In rare circumstances, static electricity or power surges may inter-...
  • Page 14: 3-Year Limited Warranty

    This warranty does not cover removal or reinstallation costs and shall not apply if the damages were found to be caused by something ecobee warrants that for a period of three (3) years from the date other than defects in materials or workmanship, including without of purchase by the consumer (“Customer”), the ecobee Smart...