Connections and control devices

1
Mains power supply switch, O/I
2
Indicator lamp, yellow, overheating
3
Indicator lamp, green, VRD function
(reduced open-circuit voltage)
4
Display, current (A) and voltage (V)
5
Knob for setting:
MMA/TIG/Arc air gauging: Current (A)
Mobile Feed mode: Voltage (V)
6
Knob for choice of electrode type
7
Knob for inductance (MIG/MAG) and arc
force (MMA)
bu21e
8
Knob for welding method
9
Connection (-): MIG/MAG: Return cable
TIG: Welding torch
MMA: Return cable or welding cable
10
Connection (+): MIG/MAG: Welding cable
TIG: Return cable
MMA: Welding cable or return cable
11
Circuit breaker, 10 A, 42 V
12
Connection of wire feed unit
13
Connection of remote control unit (option)
14
Connection of mains power supply